Instructions / Assembly
Bay Area Compliance Laboratories Corp. (Dongguan)
No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China.
The IAS Accreditation Number TL-460
Report No. R2DG181011050-10
Page 4 of 13
1.3 Testing Equipment
Device
Manufacture
Model No
Serial No
Calibration date
Calibration due date
0.3m integrating
sphere
EVERFINE
Diameter 0.3m
1011119
2017-03-09
2018-03-09
Programmable Test
Power for LEDs
EVERFINE
LED300E
1008002
2017-03-03
2018-03-03
High accuracy array
spectroradiometer
EVERFINE
HAAS-2000
1012016T
2017-03-09
2018-03-09
Standard Light
Source
EVERFINE
D062
1011093
2017-09-13
2018-09-13
Precision digital
stabilized DC power
supply
EVERFINE
WY605-V110
G115987CJ7321114
2017-03-03
2018-03-03
Multilayer aging
machine
BACL
B2-270
20015
2017-03-03
2018-03-03
Multilayer aging
machine
BACL
B2-270
20005
2017-09-01
2018-09-01
Digital CC&CV DC
Power Supply
EVERFINE
WY5015
11060002
2017-07-07
2018-07-07
Digital CC&CV DC
Power Supply
EVERFINE
WY5015
11090007
2017-03-03
2018-03-03
1.4 Drive Level
Samples are driven with a constant direct current (DC) during maintenance test, photometric and electrical measurement. The current
value was regulated to within ±3% of the specified value of the manufacturer during maintenance test, and was within ±0.5% during
photometric and electrical measurement test.
1.5 Ambient Conditions for Maintenance Test
For lumen maintenance test, samples within one data set, were installed on cooling boards in thermal chambers with minimal
ambient airflow. The case temperature and ambient temperature was monitored by thermocouples which one was soldered to the
coldest DUTs’ case (TMP
LED
) location, while the other is mounted at a distance of 5 mm above the TMP location.
During life testing, TMP
LED
of the coldest LEDs were maintained at a temperature that was greater than or equal to 2°C below the
corresponding nominal case temperature. Surrounding air was maintained at a temperature that was greater than or equal to 5°C
below the corresponding nominal case temperature. Thermocouples were shielded from direct DUT optical radiation and comply with
ASTM E230 Table 1 “Special Limits”.
Samples were connected to DC power supply in series circuits with a constant current. The forward current was regulated to within
±3% of the specified value of the manufacturer.
The relative humidity within chamber was kept less than 65% during test.
For photometry measurement, the ambient temperature during test was set to 25°C ± 2°C, RH <65%.
1.6 Photometric Measurement Method and Uncertainty
Integrating sphere and spectroradiometer is used to measure luminous flux and chromaticity coordinate u’v’. 2π measurement was
used and sample was drived by DC power supply. The forward current was regulated to within ±0.5% of the nominal value. The test
system was calibrated by halogen reference lamp. The ambient temperature during test was set to 25°C ± 2°C, RH <65%. The
temperature measurement point was located in the sphere and the temperature was detected by a temperature probe.
The uncertainty of the light output measurements is U=1.59% (K=2), at the 95% confidence level. The uncertainty of the correlated
color temperature measurements is U=21K (K=2), at the 95% confidence level.
The uncertainty of the temperature is U=0.8671°C (K=2), at the 95% confidence level.
1.7 Statement of Traceability
Bay Area Compliance Laboratories Corp. (Dongguan) attested that all calibration has been performed using suitable standards
traceable to National Primary Standards and International System of Units (SI).