Installation Guide
Report No.: BLC1807011E-A
Laboratory: Shenzhen Belling Test Laboratory A2LA Certificate# 4810.01
Building No3 3rd floor, room 303, No 2-10 south Jinlong avenue, Sand Lake community, Biling
street, Pingshan district, Shenzhen, Guangdong,CN. Website: http://www.bltst.com
Report Format Number BL-FM-SA-012
4 / 17
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction BL-QP-033)
Test date
2018-7-15
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
AST-CP3B-150WSASA1-a40
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
BLC180701
1E-A1
120.0
60
1.2570
150.39
0.997
5.54
277.0
60
0.5683
145.92
0.927
14.35
DLC Pass Criteria
>= 0.9(-3%)
<= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120.0
R1
81
R9
5
Frequency (Hz)
60
R2
90
R10
75
CCT (K)
4027
R3
96
R11
80
Duv
0.00091
R4
81
R12
61
Chromaticity (x, y)
x=0.3799 y=0.3784
R5
81
R13
83
Chromaticity (u’, v’)
u(u')=0.2241 v'=0.5022
R6
86
R14
98
Color Rendering Index (CRI)
82.7
R7
85
R15
74
R9
5
R8
63
--
--
Photometric Measurement – Goniophotometer Method:
Parameter
Result
DLC V4.3 Pass Criteria
Test Voltage (V)
120.0
277.0
--
Frequency (Hz)
60
60
Total Luminous (lm)
19727.5
19314.1
>=10000(-10%)
Luminous Efficacy (lm/W)
131.18
132.36
Premium: >= 120(-3%)
Most worst Luminous/Highest Watts
128.43
Zonal lumens in the 0-40° zone (%)
41.8
--
>=40(-3)
Zonal lumens in the 40-70° zone (%)
46.2
--
>=40(-3)
Beam Angle (°)
117.6
--
--
Center Beam Candle Power (cd)
6413
--
--