Installation Guide
Report No.: BLC1807011E-A
Laboratory: Shenzhen Belling Test Laboratory A2LA Certificate# 4810.01
Building No3 3rd floor, room 303, No 2-10 south Jinlong avenue, Sand Lake community, Biling
street, Pingshan district, Shenzhen, Guangdong,CN. Website: http://www.bltst.com
Report Format Number BL-FM-SA-012
14 / 17
2.2 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction BL-QP-033)
Test date
2018-6-3
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
AST-CP3B-150WSASA1-a57
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
BLC180701
1E-A2
120.0
60
1.2505
149.72
0.9977
5.39
277.0
60
0.5656
145.38
0.928
14.61
DLC Pass Criteria
>= 0.9(-3%)
<= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120.0
R1
82
R9
5
Frequency (Hz)
60
R2
91
R10
78
CCT (K)
5527
R3
94
R11
79
Duv
0.00251
R4
80
R12
59
Chromaticity (x, y)
x=0.3308 y=0.3446
R5
82
R13
85
Chromaticity (u’, v’)
u(u')=0.2044 v'=0.4791
R6
86
R14
98
Color Rendering Index (CRI)
83.3
R7
85
R15
57
R9
5
R8
66
--
--
Photometric Measurement – Sphere-Spectroradiometer Method:
Parameter
Result
DLC V4.3 Pass Criteria
Test Voltage (V)
120.0
277.0
--
Frequency (Hz)
60
60
Total Luminous (lm)
20221.18
19856.00
>=10000(-10%)
Luminous Efficacy (lm/W)
135.06
136.58
Premium: >= 120(-3%)
Most worst Luminous/Highest Watts
132.62