Use and Care Manual
NVLAP LAB CODE 201011-0
Report No.: GZE160706-F
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
4 / 10
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
Test date
2016-08-05
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
SNC-CLH-95W1A1-E 4000K
Electrical Measurement in GE M250R2 Roadway Lamp:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
GZE160706-
F1
120.0
60
0.7835
93.15
0.9907
6.23
277.0
60
0.3667
91.70
0.9028
17.90
DLC Pass Criteria
>= 0.9(-3%)
<= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method in GE M250R2
Roadway Lamp:
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120.0
R1
71
R9
0
Frequency (Hz)
60
R2
80
R10
50
CCT (K)
3898
R3
85
R11
66
Duv
0.0000
R4
71
R12
39
Chromaticity (x, y)
x=0.3851 y=0.3797
R5
69
R13
72
Chromaticity (u’, v’)
u'=0.2270 v'=0.5036
R6
70
R14
91
Color Rendering Index (CRI)
73.1
R7
82
R15
66
R9
0
R8
56
--
--
Photometric Measurement – Goniophotometer Method in GE M250R2 Roadway
Lamp:
Parameter
Result
DLC V4.0 Pass Criteria
Test Voltage (V)
120.0
277.0
--
Frequency (Hz)
60
60
Total Luminous (lm)
10622
10458
In luminaire:
>=10000 (-10%)
Luminous Efficacy (lm/W)
114.03
114.05
In luminaire:>=95(-3%)
Zonal lumens in the 0-90° zone (%)
99.8
--
>= 100(-1)
Zonal lumens in the 80-90° zone (%)
0.4
--
<=10(+3)
Beam Angle (°)
121.3
--
--
Center Beam Candle Power (cd)
2857
--
--