User Manual

Quinta – Charger
26
5.2 Notes for Microphone Units and Rechargeable
Batteries
To achieve a 100% battery capacity of the rechargeable batteries,
all microphone units should have 2 complete charging cycles
(charging and discharging) at least. Only after several charging and
discharging cycles, the rechargeable batteries will achieve their
full capacity.
The Quinta MU microphone units are provided with high-
performance nickel-metal hydrid (NiMH) batteries. These
guarantee operating times of approx. 20 hours. It takes about
2.5 hours to charge them.
The service life of the batteries largely depends on the manner in
which they are looked after and on how well the user recharges
them. To extend the service life of the batteries for as long as
possible, the following charging cycle is recommended:
Do not keep the microphone units in the charging case when
it is switched on.
Only put the microphone units in the charging case before a
conference / application and fully charge them until the “fully
charged” status is shown.
In particular, when the microphone units are inserted, the
charging case should not be constantly switched on and off.
For each charging cycle, there is an initial 5-minute charge to
check the battery status. If the case with the microphone units
is switched on every day (for example, because the mains is
switched off automatically or by a cleaner), the microphone
units will be slowly but constantly overcharged and this will
damage the batteries.
The NiMH batteries used minimise the so-called “memory
effect”, but their capacity is reduced when they are only
partially discharged on a regular basis. For this reason, the
microphone units should be fully discharged every three
months until they switch off automatically. They can then be
fully recharged. This procedure can, if necessary, be repeated
a second time.
If, despite this measure, the microphone unit does not operate
for a sufficiently long period of time, the battery has reached
the end of its service life and must be replaced. The typical
service life of the battery is greatly dependent on whether or
not the above points are observed. This is why batteries are
not covered by warranties. If the above points are observed, a
battery typically has a service life of at least two years or
500 complete charging cycles, depending on which occurs
first.
Note:
If an error has occurred, try to restart the charging
process. If the LEDs are still flashing rapidly, please
contact your beyerdynamic dealer.
For a reliable charging of the rechargeable batteries and
in order to avoid long-term damages the ambient
temperature must not exceed +35 °C [95 °F] during
charging.
5. Quinta CD 2 Charger in the
Quinta CC 2 | CC 2 / 600 Case and
Quinta CD 3 in the Quinta CC 3 Case
Quinta CC 2 is a modular charging and transport case for the Quinta
MU 23/22/21 microphone units. The basic version the Quinta CC 2
consists of a top cover (Quinta CT 2), a charger (Quinta CD 2) for 10
Quinta MU 23/22/21 microphone unit and a bottom with casters
(Quinta CW 2). This version is suitable for Quinta MU 23/22/21
microphone units using the Classis GM 313 Q, GM 314 Q and
GM 315 Q microphones.
For microphone units using the Classis GM 316 Q microphone the
version Quinta CC 2 / 600 with a higher top cover (Quinta CT 2 / 600)
will be available.
Quinta CC 3 is a modular charging and transport case for the
Quinta MU 33/31 microphone units. The basic version the Quinta CC3
consists of a top cover (Quinta CT 2), a charger (Quinta CD 3) for 12
Quinta MU 33/31 microphone unit and a bottom with casters
(Quinta CW 2).
With the Quinta CD 2 charger integrated in the Quinta CC 2 or
CC 2 / 600 case you can charge a maximum of 10 Quinta MU
23/22/21 microphone units with the Classis GM 313 Q, 314 Q,
315 Q or Classis GM 316 Q microphone. With the Quinta CD 3
charger integrated in the Quinta CC 3 case you can charge a
maximum of 12 Quinta MU 33/31 microphone units. The charging
state can be seen from the outside through a glass panel.
The Quinta CC 2 or CC 3 charging and transport case can be
extended with another Quinta CD 2 or CD 3 charger for 10 or 12
microphone units. Because of a possible instability more than two
Quinta CD 2 or CD 3 chargers must not be piled up. Quinta CD 2
chargers that contain microphone units with the Classis GM 316 Q
microphone cannot be piled up because of the microphone length.
For the Quinta CC 2 or CC 2 / 600 or CC 3 charging and transport
case there is an optional compartment available for storing the
Quinta CU control unit and accessories such as cables and
gooseneck microphones.
5.1 Charging Process
1. Connect the charger to AC power and switch it on. The switch
will illuminate.
2. Put the switched-off microphone units into the charging
compartments. If microphone units are switched on, they are
switched off automatically. When the microphone units are used
again, they must be switched on by hand.
3. The charging process is indicated by the LED of the gooseneck
and can be seen from the outside through a glass panel.
LED indicator when the batteries are recharged:
a) Gooseneck LED or LED strips
are flashing red. . . . . . . . . . . . . . . Battery is charged
b) Gooseneck LED or LED strips
illuminates red permanently. . . . . . Battery is completely full
c) Gooseneck LED or LED strips
are flashing red rapidly . . . . . . . . . Error
After some time the capacity of the rechargeable batteries is
reduced technically. This will reduce the operating time.
It is normal that the rechargeable batteries are heated up during
the charging process.
Clean the charging contacts with spirit or isopropyl alcohol from
time to time. While cleaning avoid contact with the painted
surface.