User Manual

Quinta – Microphone Units
24
5. How to Mute Audio IN ports and clear all active delegate units
By pressing the function button a second time, mute is
released. By pressing the function button a third time, the
audio input is muted again and all active delegate units will be
cleared etc.
The function button illuminates red.
6. How to Mute Audio OUT ports
First push mutes the port, the next one enables it, third one
mutes again etc.
If the chairman presses the function button of his/her micro-
phone unit, the audio output of the Quinta CU control unit will
be muted. The function button illuminates red.
7. “RS 232 Message” Function
A command is sent via the RS 232 serial interface from the
Quinta CU control unit and a programmed function is carried
out via a media control system for instance (e.g. light control).
At the same time a command is also sent for other functions
via the RS 232 serial interface from the Quinta CU control
unit.
8. Command A/B
Two different commands according to the duration of the push
of the function button.
< 1 second = command “Short press string” is transmitted
> 1 second = command “Long press string” is transmitted
These commands can be set individually with the Quinta
Conference software.
Quinta MU 33
Quinta MU 23 Quinta MU 23 V