User's Manual

Trouble Shooting
E
42
7. Battery Charging with external Power Supply Unit
The MCW-D microphone units can be also charged with the external
CA 2457 power supply unit, which is connected to the DC socket .
The charging process is indicated by the operating control LED .
LED indication during charging the battery:
a) Operating control LED is flashing red . . . . . . . . . . . . . . Battery is
charged
b) Operating control LED illuminates red permanently . . . Battery is full
c) Operating control LED is flashing red rapidly. . . . . . . . . Error
Rear view
Important:
After some time the capacity of the rechargeable batteries is
reduced technically. This will reduce the operating time.
It is normal that the rechargeable batteries are heated up
during the charging process.
The charging time is around 5 hours when the battery is
completely empty.
If the microphone unit is switched on during the charging
process, the LED will illuminate green.
8. Trouble Shooting
If problems occur that you do not find listed below, the MCW-D system should be adjusted to the standard configuration with
the MCW-D 50 Conference software. Please refer to the appropriate manual.
Problem
LED flashes red rapidly
Power LED flashes
Microphone unit goes off
Allocation is not possible
Microphone unit cannot be switched
on
Possible Cause
Control unit is not switched on
Microphone unit is not within the
range of the control unit
Frequency bands have been
configured incorrectly
Battery is almost empty
Low battery warning to indicate that
the battery is almost empty
Check if the battery is still full
PIN Code is activated
Control unit is not switched on
All channels are occupied
Check the number of open micro-
phones (NOM) with the MCW-D 50
Conference software
Microphone unit is not within the
range of the control unit
Check the adjusted frequency bands
Interference caused by WLAN
Control unit is not switched on
Check the number of open micro-
phones (NOM) with the MCW-D 50
Conference software
Check the battery
Microphone unit is not within the
range of the control unit
Solution
Switch on the control unit
Reduce the distance between
control unit and microphone units
Check the adjusted frequency bands
with the MCW-D 50 Conference
Software
Recharge the battery inside the
microphone unit
If the battery is empty recharge it
Deactivate PIN Code
Switch on the control unit
Switch off an activated microphone
If possible increase the number of
open microphones (NOM) with the
MCW-D 50 Conference software
Reduce the distance between
control unit and microphone units
Use the standard adjustments
mentioned in the MCW-D 50
Conference manual
Select another frequency band for
the RF module(s) with the MCW-D 50
Conference Software
Switch on the control unit
If possible increase the number of
open microphones (NOM) with the
MCW-D 50 Conference software
If the battery is empty recharge it
Reduce the distance between
control unit and microphone units
2
2
3
3
7
3