User's Manual

MCW-D 50 – Setting up
48
8. Battery Charging with external CA 2457 Power Supply Unit
The MCW-D microphone units can also be charged with the external
CA 2457 power supply unit, which is connected to the DC socket or .
The charging process is indicated by the operating control LED or .
LED indication during charging the battery:
a) Operating control LED is flashing red . . . . . . . . . . . . . . . Battery is charged
b) Operating control LED illuminates red permanently . . . . Battery is full
c) Operating control LED is flashing red rapidly. . . . . . . . . . Error
Important:
After some time the capacity of the rechargeable batteries is reduced
technically. This will reduce the operating time.
It is normal that the rechargeable batteries are heated up during the
charging process.
When the battery is completely empty, the charging time is around
5 hours with the MCW-D 521 / 523 and approx. 7 hours with the
MCW-D 531 / 533.
If the microphone unit is switched on during the charging process, the
LED or will illuminate green.
2
2
3
3
Rear view MCW-D 521 / 523
9. Trouble Shooting
If problems occur that you do not find listed below, reset the MCW-D system to the standard configuration with the MCW-D 50
Conference software. Please refer to the appropriate manual.
Problem
LED or flashes red rapidly
Power LED or flashes
Microphone unit goes off
Allocation is not possible
Microphone unit cannot be switched on
Possible Cause
Control unit is not switched on
Microphone unit is not within the range
of the control unit
Frequency bands have been
configured incorrectly
Battery is almost empty
Low battery warning to indicate that the
battery is almost empty
Check if the battery is still full
PIN Code is activated
All channels are occupied
Check the number of open microphones
(NOM) with the MCW-D 50 Conference
software
Microphone unit is not within the range
of the control unit
Check the adjusted frequency bands
Interference caused by WLAN
System operates in the PC
controlled mode (Controller)
Control unit is not switched on
Check the number of open microphones
(NOM) with the MCW-D 50 Conference
software
Check the battery
Microphone unit is not within the range
of the control unit
Solution
Switch on the control unit
Reduce the distance between
control unit and microphone units
Check the adjusted frequency bands
with the MCW-D 50 Conference
Software
Recharge the battery inside the micro-
phone unit
If the battery is empty, recharge it
Deactivate PIN Code
Switch off an activated microphone
If possible increase the number of open
microphones (NOM) with the MCW-D 50
Conference software
Reduce the distance between
control unit and microphone units
Use the standard adjustments
mentioned in the MCW-D 50
Conference manual
Select another frequency band for the
RF module(s) with the MCW-D 50
Conference Software
Set the system into the autonomous
operating mode with the MCW-D 50
Conference Software
Switch on the control unit
If possible increase the number of
open microphones (NOM) with the
MCW-D 50 Conference software
If the battery is empty recharge it
Reduce the distance between
control unit and microphone units
7
3
Rear view MCW-D 531 / 533
15
15
16
3
16
16
16
20