Technical information

43The product range may vary in different regions.
Control unit DC800
Door controller for one door
Programmable via integrated keypad or from a PC with the Entro Lite SW, but it can
also work as a door controller in a larger Entro system.
Includes functions like calendar clock, event buffering, door monitoring, anti-passback,
bank lobby function.
Very easy to upgrade to a multi-door solution by using the Entro Lite software together
with the USB-RIF/2 interface converter.
The DC800 is also a good alternative when a split mounted code lock is required
because it includes a calendar clock (no timers needed). Just install a M43 keypad
outside and/or inside the door.
Article Number: 31-620
Technical Data
Housing:
Wallmounted hosing with lock.
Colour:
White
Environment:
Indoor
Temperature:
-35 to +50 °C. 0 to 90% relative humidity.
Voltage:
10 to 40 V DC , 8–28 VAC.
Current:
200 mA (24V DC). Reader exklusive.
Dimensions:
250 (W) x 128 (H) x 54 (D) mm.
Door Capacity:
1
Code capacity:
10
Card capacity:
1000
Time Schedules:
10 (using up to eight time zones).
Time Zones:
80
Event log:
1000
Inputs:
Door contact for indicating closed/open door.
Exit button request with delay.
Outputs:
Voltage-free change over contact (lock relay), max. 2A, 30 VDC.
Voltage-free change over contact (extra relay) max. 2A, 30 VDC.
Keypad M65
Connects with four-wire to a DC800 or Telecode Controller. One for each door where
only code functions are needed. For flush mounting use BB3 flush mounting unit.
The design, cast metal with stainless steel keys and security lock, allows both in- and
outdoor use.
Article Number: 41-524
Technical data
Housing:
Cast metal with stainless steel keys and security lock.
Environment:
Indoor or outdoor use (IP54 design). In very exposed locations, use
SH2 or SH1 rain cover.
Temperature:
-35 to +50 °C
Voltage:
12 to 24 V DC, Powered from controller.
Current:
50 mA
Dimensions:
80 (W) x 140 (H) x 40 (D) mm
Inputs:
Tamperswitch for internal alarm.
ACCESS PRODUCTS
Split Codelocks
Contents >>