Technical information
The product range may vary in different regions.42
If there are several doors to be controlled, or higher security is requested, you can install a split
mount codelock control unit together with one or more keypads. Since all doors are controlled from
the same place, it is very easy and convenient to change all codes at the same time. Our control
unit allows for a multi-door solution. You mount the control unit indoors and then connect up to
six keypads outdoors. In this case the electronics is secured and only the keypad is outdoors. The
units connect with a four-wire cable.
Control unit KC5000
The KC5000 is a programmable and split mounted control unit working together with
the M65 keypad. It is ready-made for six doors and the right code activates a relay in
the keypad. KC5000 is easy to programme via integral keypad and display, and could
also be remotely programmed with REMO PC-based software. It should be mounted
indoor and has a discrete design to easily blend into any environment. Power supply
is included at delivery.
Article Number: 11-310
Technical data
Interfaces:
Connection to keypad M65, where the lock then is connected. RS232
for PC or modem.
Housing:
Plastic housing with security lock.
Colour:
Light Grey
Environment:
Indoor use only.
Temperature:
0 to +50 °C
Voltage:
24 to 24
Current:
250 mA in standby.
Dimensions:
140 (H) x 60 (D) mm
Door capacity:
1–6 keypads M65 are connected with a four-wire.
Code capacity:
99
Time zones:
99
Serial Interface:
RS232: 9600 bps,no parity, 8 bits, 1 startbit, 1 stopbit.
Opening time:
1–999 seconds.
Keypad M65
Connects with four-wire to a KC5000 or Telecode Controller. One for each door where
only code functions are needed. For flush mounting – use BB3 flush mounting unit.
The design, a cast metal with stainless steel keys and security lock, allows both in-
and outdoor use.
Article Number: 41-524
Technical data
Housing:
Cast metal with stainless steel keys and security lock.
Environment:
Indoor or outdoor use (IP54 design). In very exposed locations, use
SH2 or SH1 rain cover.
Temperature:
-35 to +50 °C
Voltage:
12 to 24 V DC, Powered from controller.
Current:
50 mA
Dimensions:
80 (W) x 140 (H) x 40 (D) mm
Inputs:
Tamperswitch for internal alarm.
Split Codelocks
ACCESS PRODUCTS
Contents >>