User manual
BC615 Installation and User Manual 57
Technical information
Power supply: 8 – 24V AC, 12 – 35 V DC.
Max power
consumption: BC615: 70 mA.
BC615Prox & BC615EM: 120mA.
Lock relay: Max 2A, 30 V DC.
Duress output: Open collector to 0 volt. Max 500 mA, 30VDC.
Alarm output: Open collector to 0 volt. Max 500 mA, 30VDC.
Tamper switch: Max 1A, 30 V DC.
Inputs: Normally pulled high. Active when pulled low,
i.e. 0 V.
Red LED external
control: Galvanic insulation. 12-30 V DC.
Communications port: RS-232 (printer, PC or system).
Temperature range: BC615: –35° C to +50° C
BC615Prox & BC615EM: –30° C to +50° C
(at 90 % relative air humidity).
Housing protection
class: IP54
Dimensions: 108 x 160 x 45 mm (WxHxD).
Minimum PC system requirements:
• 486 processor (Pentium recommended)
• 16 MB RAM
• At least 20 MB free disk space
• 3,5” floppy disk unit
• VGA screen
• Serial port and Parallel port
• Windows 95 (OSR2
)
BC615Prox is notified, according to the R&TTE Directive (1999/5/IEC), for use in
following countries: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland,
Ireland, Italy, Spain, Sweden, the Netherlands and United Kingdom.