Technical information

Bewacard 610 Technical Manual 27
Technical information
Power supply: 12-24 V AC/DC.
Max power consumption: BC610: 60 mA.
BC610Prox & BC610EM: 110 mA.
Lock relay: Max 2A, 30 V DC.
Duress output: Open collector to 0 volt. Max 500 mA, 30 V
DC.
Tamper switch: Max 1A, 30 V DC.
Inputs: Normally pulled high. Active when they are
pulled low, i.e. 0 V.
Temperature range: BC610: –35° C to +50° C, at 90 % relative
air humidity.
BC610Prox & BC610EM: –30° C to +50°
C, at 90 % relative air humidity.
Housing protection class: IP54
Dimensions: 108 x 160 x 45 mm (WxHxD).
BC610Prox is notified for use in following countries: Austria, Belgium, Denmark,
Finland, France, Germany, Greece, Iceland, Ireland, Italy, Spain, Sweden, the
Netherlands and United Kingdom.