PH specsheet

Store# 
Quantity 
Model Specified 
Location 
Reach-In Warming Cabinets 
Models: PH1-1S, PH2-1S, PH1-1S-PT, PH2-1S-PT 
(PT) Pass-Thru Models 
 PLAN VIEWS 
MODEL PH1-1S 
1 Section 
PH2-1S 
2 Section 
PH1-1S-PT 
1 Section 
Pass-Thru 
PH2-1S-PT 
1 Section 
Pass-Thru 
EXTERNAL DIMENSIONAL DATA 
Length Overall (inches) / (mm)  26 1/2” / 673  52 1/8” / 1324  26 1/2” / 673  52 1/8” / 1324 
Depth Overall (inches) / (mm) 
Includes handle(s) 
34 1/2” / 876 
36” / 914  34 1/2” / 876 
36” / 914 
Height Overall— (inches) / (mm) 
Includes adjustable legs 
84” / 2134  84” / 2134  84” / 2134  84” / 2134 
Number of doors  1 2  2  4 
Depth with Door Open 90 
o
  58 1/2”  65 1/4”  84 5/8”  98 1/8” 
Clear Door Width  21 1/8”  21 1/8”  21 1/8”  21 1/8” 
Clear Full Door Height  55 1/4”  55 1/4”  55 1/4”  55 1/4” 
INTERNAL DATA       
NET Capacity (cubic ft.) / (Liters)  21.5 / 609  46.5 / 1317  23.7 / 671  48 / 1359 
Number of Shelves  3  6  3  6 
Shelf Area (square feet)  17.1  36  17.1  36 
ELECTRICAL DATA       
Cabinet Voltage  208-240/60/1  208-240/60/1  208-240/60/1  208-240/60/1 
Max. Fuse Size T.D.  15 Amps  20 Amps  15 Amps  20 Amps 
Feed Wires  2  2  2  2 
Heater Watts per section (@ 240V)  1500  1500  1500  1500 
Total Wattage (Heaters & Fan @ 240V)  1500  3000  1500  3000 
Total Amperes  6.3  13.0  6.3  13.0 
WEIGHT DATA       
Gross Weight (Crated lbs)  310 540*  355  620* 
Gross Weight (Crated kg)  141 245  161  281 
COMMON FEATURES 
*Note: Dimensional tolerance +- 1/4” Metric dimensions (MM) 
*Note: For approximate Pass-Thru weights add 15%. 
NOTE: If cabinet is located 
directly against wall an all 
around clearance of 2” is 
required, and a minimum 
clearance of 10” under ceiling. 
BEVERAGE-AIR
® 
CORPORATION 
3779 Champion Blvd. • Winston-Salem, NC 27105 USA • (336) 245-6400 • Fax (336) 245-6453 • (888) 845-9800 • www.beverage-air.com 
Specifications are subject to change without prior notice.  06/10 