Installation manual
Compressor Model Number Copeland KAGB-005E-IAA
Recommended Operating Temp. Range (F/C) 0°F to -40°F (-18°C to -40°C)
Cabinet Volts 115/60/1 
Expansion Device Sporlan Y1232-FBS 1/4
Charge Refrig. Type / Oz. / Grams R404A / 22 oz. / 623.7 grams
ELECTRICAL & REFRIGERATION SPECIFICATIONS
Hardening Cabinet, Solid, 1-Door Freezer
SYSTEM COMPONENTS 
AMBIENT 70°F / 21.1°C 80°F / 27°C 90°F / 32.5°C
Cavity Temp. (F/C) -20 / -29 -20 / -29 -20 / -29
Suction Pressure (PSIG / Kpa) 4.0 / 27 6.0 / 41 6.6 / 46
Discharge Pressure (PSIG / Kpa) 180.0/1241 228/1572 234/1613
Compressor Amps 7.8 7.9 7.8
Total Refrigeration Amps 10.3 10.3 10.2
SYSTEM PERFORMANCE
Compressor Model Number Copeland KAJB-007E-IAA
Recommended Operating Temp. Range (F/C) 0°F to -40°F (-18°C to -40°C)
Cabinet Volts 115/60/1 
Expansion Device Sporlan Y1232-FBS 1/4
Charge Refrig. Type / Oz. / Grams R404A / 22 oz. / 623.7 grams
ELECTRICAL & REFRIGERATION SPECIFICATIONS
Hardening Cabinet, Solid, Quad Door Freezer
SYSTEM COMPONENTS 
AMBIENT 70°F / 21.1°C 80°F / 27°C 90°F / 32.5°C
Cavity Temp. (F/C) -16 / -27 -18 / -28 -18 / -28
Suction Pressure (PSIG / Kpa) 2.6 / 18 3.6 / 25 4.0 / 28
Discharge Pressure (PSIG / Kpa) 200/1379 224/1544 245/1689
Compressor Amps 7.9 7.9 7.8
Total Refrigeration Amps 11.1 11.0 10.9
SYSTEM PERFORMANCE
NOTE: REFER TO SERIAL DATA PLATE FOR REFRIGERANT TYPE & CHARGE.
22 ELECTRICAL / REFRIGERATION SPECIFICATIONS