Installation manual
Compressor Model Number Copeland KAJB-007E-1AA
Cabinet Volts 115/60/1 
Expansion Device Sporlan Y1232-FBS 1/4
Charge Refrig. Type / Oz. / Grams 404A / 18 oz. / 510 grams
ELECTRICAL & REFRIGERATION SPECIFICATIONS
Low Temp., Glass, 1-Door Freezers
SYSTEM COMPONENTS 
AMBIENT 70°F / 21.1°C 80°F / 27°C 90°F / 32.5°C
Cavity Temp. (F/C) -6 / -21 -7 / -22 -9 / -23
Suction Pressure (PSIG / Kpa) 4.0 / 27.6 4.0 / 27.6 5.0 / 34
Discharge Pressure (PSIG / Kpa) 201/1385 233/1537 247/1703
Compressor Amps 9.9 9.6 9.8
Total Refrigeration Amps 13.7 13.4 13.6
SYSTEM PERFORMANCE
NOTE: REFER TO SERIAL DATA PLATE FOR REFRIGERANT TYPE & CHARGE.
Compressor Model Number Americold HP121-1-3087
Recommended Operating Temp. Range (F/C) 0°F to -20°F (-18°C to -29°C)
Cabinet Volts 115/60/1
Expansion Device Sporlan Y1232-FBS 1/4
Charge Refrig. Type / Oz. / Grams R404A / 22 oz. / 623.7 grams
SYSTEM COMPONENTS
AMBIENT 70°F / 21.1°C 80°F / 27°C 90°F / 32.5°C
Cavity Temp. (F/C) -4 / -20 -5 / -21 -6 / -7
Suction Pressure (PSIG / Kpa) 12 8.7 12.5
Discharge Pressure (PSIG / Kpa) 194 210 220
Compressor Amps 2.9 2.7 2.8
Total Refrigeration Amps 5.4 5.4 5.4
SYSTEM PERFORMANCE
Low Temp., Solid, 1-Door Freezer
ELECTRICAL / REFRIGERATION SPECIFICATIONS 19