hb series manual
Bi-pin Florescent Lamp Installation / Verification
(Glass Door Models Only)
a: Visual verification can be made on units without safety shields by using the identification mark on
the end of the bulb. Properly installed bulbs will have the mark centered between the halves of
the lamp holder. (See Pictures 1 and 2 below)
b: On units with shields, the identification mark cannot be seen. Physically verify that the lamp has
been rotated and locked into place. (See pictures 3 and 4 below)
c: Prior to applying power to the unit, verify that all lamps are properly installed and fully engaged in
the lamp holders. Proper lamp engagement is achieved by rotating the lamp 90 degree from its
insertion position until it snaps or clicks into below.
Caution: Improperly installed lamps may cause damage to the lighting circuit.
Beverage-Air shall have no liability whatsoever for equipment or component failures or other
damages or losses which arise as a result of improper installation of lamps.
Bi-pin lamp end identification mark
Bi-pin lamp end properly installed
into shield (Note location of
identification mark
)
Properly installed lamp with shield.
Requires physical verification that lamp
has been rotated and locked into
p
lace
Improperly installed lamp with shield.
Note that pins have not achieved full 90
de
g
ree rotation
1 2
3 4