User Manual
User Manual for FLG Glass Frosters Beverage-Air
Rev. 06/22Beverage-Air10
0
o
F
USING THE UNIT
Operation is simple, just keep it connected to the correct
power supply and the froster will maintain the internal
temperature it has been set to. Keep the doors closed as
much as possible to avoid unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
The temperature was set at the factory at 0
º
F, but you can
adjust it to your own selected temperature. 30 seconds
after adjustment, the display automatically reverts to
showing the current temperature.
The froster will automatically defrost as needed, there is
no set time for defrost. Push and immediately release the
"melting" or defrost button for a manual defrost.
Note: Holding the defrost button in too long will shut the
controller o.
The internal fan will be on when the compressor is on and
when the doors are closed.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
Select
Defrost
Increase
Decrease
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed Why What to do
dEF
Unit is defrosting Nothing. Normal operation.
Hi
Cabinet temperature too warm Conrm doors or drawers are closed.
dOr
Door is open Close door, if message does not
change, call for service.
LEA
Compressor run time too long Check doors closed. If yes, call for
service.
E01, E02, E03, E04
Sensor unplugged or has failed Call for service.