USING THE UNIT
Operation is simple, just keep it connected to the correct
power supply and the refrigerator will maintain the
internal temperature it has been set to. Keep the doors
and / or drawers closed as much as possible to avoid
unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
For best results, make certain the unit remains powered
and has achieved the desired set point before loading
it with product. Pull down time will vary depending
upon the type of unit and ambient conditions. Freshly
cooked product, or otherwise warm product placed
into the appliance will also increase the pull down time
signicantly since this model is designed for storage and
not for rapid pull down.
The temperature was set at the factory at 0
º
F, but you can
adjust it to your own selected temperature. 30 seconds
after adjustment, the display automatically reverts to
showing the current temperature.
The freezer will automatically defrost as needed, there is
no set time for defrost. Push and immediately release the
"melting" or defrost button for a manual defrost.
Note: Holding the defrost button in too long will shut the
controller o.
The internal fan will be on when the compressor is on and
when the doors are closed.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
If equipped with glass doors, holding the SC button in will
turn the cabinet light on or o.
Select
Defrost
Increase
Decrease
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed Why What to do
dEF
Unit is defrosting Nothing. Normal operation.
Hi
Cabinet temperature too warm Conrm doors or drawers are closed.
dOr
Door is open Close door, if message does not
change, call for service.
LEA
Compressor run time too long Check doors closed. If yes, call for
service.
E01, E02, E03, E04
Sensor unplugged or has failed Call for service.