INSTALLATION AND OPERATING INSTRUCTIONS for all DP and DPD Models 809-140A Rev. C: 10/28/2020 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.
User Manual for DP & DPD Beverage-Air WELCOME Congratulations on your purchase of Beverage-Air food service equipment. Every employee welcomes you to the family of satisfied Beverage-Air customers. From the earliest stages of production design, to focused steps in fabrication and assembly, rigid standards of quality are maintained by our staff of skilled employees.
User Manual for DP & DPD Beverage-Air SAFETY This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However, safe operation and maintenance are your responsibilities. CAUTION Use: When using this unit, please: • Move it carefully. If on casters be sure the casters do NOT run over the power cord. • Lock the casters when in use. • Seek help. This machine is heavy! Be sure to move with enough help to avoid tipping or dropping the cabinet.
User Manual for DP & DPD Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site. The manufacturer has designed and produced this machine with the finest in materials. The manufacturer assumes no liability for units that have been altered in any way. Alterations or part substitutions will void the warranty.
User Manual for DP & DPD Beverage-Air PRODUCT INFORMATION Model Cabinet Dimensions w x d x h (Inches) Door Count Full Load Amps Compressor HP DP46HC 46 x 36.8 x 53.125 1 4.5 1/3 DP60HC 60 x 37 x 53.25 2 4.5 1/3 DP67HC 67 x 37 x 53 2 4.5 1/3 DP72HC 72 x 37 x 53.5 2 4.5 1/3 DP93HC 93 x 36.5 x 55.5 3 7.8 1/2 DP119HC 119 x 37 x 53.125 4 7.8 1/2 DPD46HC-3 46 x 36.8 x 53.125 3 4.5 1/3 DPD60HC-2 60 x 37 x 53.25 2 4.5 1/3 DPD60HC-3 60 x 37 x 53.25 3 4.
User Manual for DP & DPD Beverage-Air CLEARANCE AND PLACEMENT Placement Consider the following when selecting a location for your cooler: • Clearance: 2 inches at back. None at sides. • Floor Load: the floor on which the cooler is located must be even and level, free from vibrations, and strong enough to support the combined weights of the unit and maximum product load. • Ventilation: Grilel area at front must be free and clear of any object or wall.
User Manual for DP & DPD Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim. Do NOT contact the manufacturer. Uncrating Note: additional clear plastic protective wrap is applied directly to any product with a glass door.
User Manual for DP & DPD Beverage-Air SHELF INSTALLATION 1. Determine the proper location for the shelf clips. The reference numbers on the pilaster can serve as a guide to ensure all clips are properly located. 2. Insert the top tab of the shelf clip into the desired hole of the pilaster. The retaining tab MUST be facing up as shown. 3. Rotate the clip downwards and insert the bottom tab into the matching hole in the pilaster. The clip may need to be squeezed slightly during installation. 4.
User Manual for DP & DPD Beverage-Air DRAWER MAINTENANCE Drawer models are shipped with the drawers already installed in the cabinets. Drawers are designed with slides which have locking mechanisms to prevent drawers from coming off cabinets during normal opening and closing operations. See Illustration: Drawers and slides can be removed from a cabinet for cleaning purposes. To remove a drawer from a cabinet follow these instructions: 1. Open the drawer to full extension 2.
User Manual for DP & DPD Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers. Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to unsafe cabinet temperature when GFI device trips from moisture.
User Manual for DP & DPD Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct power supply and the refrigerator will maintain the internal temperature it has been set to. Keep the doors and / or drawers closed as much as possible to avoid unnecessary run time. The controller displays the current internal temperature. Adjusting the set temperature lower will NOT cause the system to lower the temperature faster.
User Manual for DP & DPD Beverage-Air SEQUENCE OF OPERATIONS REFRIGERATOR The refrigerator operates based on the air temperature measured by the probe located at the return air.
User Manual for DP & DPD Beverage-Air Electronic Controller DEFROST (ESC) UP SELECT (OK) DOWN Control Panel Display Defrost LED Alarm LED On fixed: Defrost active On fixed: ALARM Present Off: Defrost is off Flashing: ALARM Silenced Off: No Alarm Fan LED Compressor LED On fixed: Fan active On fixed: Compressor active Off: Fan Off Flashing: Delay, protection or activation blocked Off: No Alarm NOTE: When switched on, the instrument panel performs a lamp test for a few seconds.
User Manual for DP & DPD Beverage-Air Control Panel Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon . To turn off the relative icon will continue flashing. NOTE: If alarm exclusion times are in progress (ALA folder of the parameter table), the alarm is not signaled. 14 Beverage-Air Rev.
User Manual for DP & DPD Alarm Trigger Code Beverage-Air Automatic Outputs Clearance Comments "Hi" Air temperature is higher than "ALA->Hat• for "ALA->Htd" User configured Bl ink "Hi" with the highest temperature; If configured: cut in alarm relay, beep the buzzer High temperature alarm "Lo" Air temperature is lower than "LAt" for "Ltd'' User configured Blink "Lo" with the lowest temperatu re.
User Manual for DP & DPD Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check that hinges are tight to the cabinet. Annually Weekly interior Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up. 1. Wash with a clean sponge and a mild detergent that does not contain chlorine. 4.
User Manual for DP & DPD Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient operation. 1. 3. Pull grill carefully out and off the cabinet. Unplug unit from power supply. CAUTION Rotating fan blade can cause personal injury. Condenser Coil Unplug unit from power supply before beginning to clean condenser 4. Examine condenser surface, if dusty, brush and vacuum the dust and lint from the surface of the coil. Brush up and down to avoid damaging the fins.
User Manual for DP & DPD Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Smears and fingerprints Areal 20, Lac-O-Nu, Lumin Wash O’Cedar Cream Polish, Stainless Shine. Rub with cloth as directed on the package. Satisfactory for use on all finishes. Provides barrier film to minimize prints. Allchem Concentrated Cleaner. Apply with damp sponge or cloth. Rub with damp cloth.
User Manual for DP & DPD Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution No cooling - unit is silent Unit not plugged in. Fuse or circuit breaker tripped. Power cord plug loose in outlet. Connect to proper voltage circuit Replace fuse or reset breaker.
User Manual for DP & DPD Beverage-Air FOR THE SERVICE TECH Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a reminder and checklist for the service tech. Keep these in mind for R290 service: Evacuation: It is critical that a refrigeration system be leak free and internally dry.
User Manual for DP & DPD Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM Rev.
User Manual for DP & DPD Beverage-Air LIMITED WARRANTY WARRANTY (Warranty valid in USA and Canada) BEVERAGE-AIR THREE (3) YEAR PARTS AND LABOR WARRANTY: Also, this extended compressor-part only warranty does NOT apply to any electrical controls, condenser, evaporator, fan motors, overload switch, starting relay, capacitors, temperature control, filter/drier, accumulator, refrigeration tubing, wiring harness, labor charges, or supplies which are covered by the warranty above.
User Manual for DP & DPD Beverage-Air LIMITED WARRANTY (CONTINUED) With the exception of Blast Chillers product is designed for maintaining temperature and not bringing food to a desired temperature therefore cannot be held responsible for this function under warranty. Units must be in a conditioned environment or warranty will be void. Condensing coils must be cleaned at regular intervals. Failure to do so can cause compressor malfunction and will void warranty.
User Manual for DP & DPD Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below.