Owners Manual
User Manual for CT Freezer / Refrigerator Beverage-Air
Rev. 10/20 Beverage-Air 15
38.0
o
F
USING THE UNIT
Operation is simple, just keep it connected to the correct
power supply and the Cross Temp™ freezer/refrigerator
will maintain the internal temperature it has been set
to. Keep the doors closed as much as possible to avoid
unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
The temperature was set at the factory at 38
º
F, but you
can adjust it to your own selected temperature. Push
and release the Increase or Decrease buttons to make
a change. 30 seconds after adjustment, the display
automatically reverts to showing the current temperature.
The Cross Temp system is capable of changing from a
refrigerator setting of 40 degrees F. to a freezer setting
of -15 degrees F. by changing the temperature setting. No
other adjustment is needed. The reverse is also available.
When switching from refrigerator to freezer or freezer
to refrigerator, remove all product before making the
change. Add product ONLY after the cabinet has reached
the new temperature.
The Cross Temp will automatically defrost as needed,
there is no set time for defrost. Push and immediately
release the "melting" or defrost button for a manual
defrost.
Note: Holding the defrost button in too long will shut the
controller o.
The internal fan will be on when the compressor is on and
when the doors are closed.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
If equipped with glass doors, holding the SC button in will
turn the cabinet light on or o.
Select
Defrost
Increase
Decrease
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed Why What to do
dEF
Unit is defrosting Nothing. Normal operation.
Hi
Cabinet temperature too warm Conrm doors or drawers are closed.
dOr
Door is open Close door, if message does not
change, call for service.
LEA
Compressor run time too long Check doors closed. If yes, call for
service.
E01, E02, E03, E04
Sensor unplugged or has failed Call for service.