Owners Manual
Before connecting your equipment, check that the electrical data on the data plate match your
electrical output.
IMPORTANT NOTICE: PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN
APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAMEPLATE AMPS.
The shelves and holders have been fixed to the inside floor of the unit to prevent their loss during
transportation.
Insert the shelf brackets in the pilaster notches making sure they are at the same level such that the
shelves remain horizontal.
IMPORTANT: The products on each shelf must leave three to five centimeters of free clearance
between them and the next shelf in order to allow proper air circulation.
The CDRHC series of units are not intended to be a pull down refrigerator and as such the product
must be loaded at their intended merchandising temperature. Before loading products, allow the
equipment to operate empty for at least two hours.
When loading products:
- Do not block the lower ventilation grille with the packages about to be loaded.
- Do not block the return vents that ensure a proper refrigerated air circulation.
- Do not over hang the shelf.
- Do not press the product against the rear wall
- Never exceed the shelf weight limits.
www.beverage-air.com
|
5
POSITIONING SHELVES
PRODUCT LOADING
ELECTRONIC TEMPERATURE CONTROL
The unit is provided with an electronic temperature control that controls the operation of the unit
based on the temperature of the air entering the evaporator at the front of the unit.
In order to achieve the desired product temperature, the electronic control is factory adjusted to turn
off the refrigeration system at 35ºF and start it at 39.5ºF.
When you plug the unit in, the control display will illuminate. However, there is a start-up delay of
2 minutes before the compressor(s) are energized. This delay avoids the possibility that during a
power failure the compressors are forced to restart before the refrigerant pressures are equalized.
The control has been factory-adjusted with a defrosting cycle scheduled to last 6 minutes every hour
to ensure that the evaporator performs without any ice build-up.
None of the factory-programmed electronic control parameters can be modified unless an access
code is entered (only your distributor’s technical personnel have that code).
UNIT OPERATIONS AND COMPONENTS