Owners Manual
User Manual for BZ Refrigerators Beverage-Air
Rev. 02/22 Beverage-Air 21
CONDENSER CLEANING
Keeping the condenser coil clean is critical to ecient
operation.
1. Unplug unit from power supply.
2. Remove the single Phillips head screw at the bottom
of the front panel
3. Lift upwards on the front panel to remove
4. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the ns.
Use care to not disturb the wires connected to the
controller.
__________________________________________
Note: If the coil is greasy, the coil will need to be cleaned
with coil cleaner and that should be left to an experienced
technician.
__________________________________________
5. To reinstall the front panel line up the keeper screws
behind the panel and rmly pull downwards
6. Reinstall the Phillips head screw
7. Return grill to unit.
Note: Air lters are not recommended as they restrict
the ow of cooling air.
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
Push Panel Up to Release
From Screw Heads Behind
Panel
Remove Screw
Condenser Surface