■ Time Interval
Enter the time interval within which the authorization code security 
violations must occur. The range for the time interval is one minute 
to eight hours (0:01 to 7:59), and is entered in the form x:xx. For 
example, if you want the time interval to be one minute, enter 
0:01. 
If you want the time interval to be seven and one-half hours, enter 
7:30. The system default is 0:03.
■ Announcement Extension
Enter an extension that is assigned to an SVN authorization code 
announcement. The announcement must be recorded for the SVN 
referral call to be made. A repeating announcement is suggested, 
especially if the SVN referral call might go to an answering machine. 
2. Administer an “asvn-halt” button on any station/attendant console. 
The location of the SVN button can be determined by entering the display 
svn-button-location command. Activation of this button stops the 
placement of authorization code referral calls until the button is 
deactivated.
Administering the station security code 
component
Page 2 of the Security-Related System Parameters screen allows the user to 
administer parameters relevant to Station Security Codes. This page appears only 
for Release 5 versions or later of G3. To administer parameters for station security 
codes:
1. Access the Security-Related System Parameters screen by entering the 
change system-parameters security command from the command line 
interface.
2. Populate the following fields:
■ Minimum Station Security Code Length
Enter a minimum station security code length (3 through 8). This 
value is used to verify all subsequent security code changes; 
however, any existing security codes are assumed to be valid. 
Default is 
4.
■ SVN Station Security Code Violation Notification 
Enabled?
Activate (by entering y) or deactivate (by entering n) the security 
violation notification for station security codes. Default is 