Instruction manual
Permanently disabling remote access
Issue 9 May 2003
12-3
17. For DEFINITY G1 and System 75, use change ars fnpa a00 group 8 (a 
equals 
0 through 5), change ars hnpa n00 group 8 (n equals 2 through 
9), and change rnx n00 group 8 (n equals 2 through 9) to enter the Route 
Pattern where you want to allow calls. 
The dialed string entries are already specified, so enter the Route Pattern 
number only. Here are some considerations:
— The HNPA table has the default value for the route pattern set to 
1, 
so you may not want to administer any trunk group to that route 
pattern. Use 
change route-pattern 1 to delete any trunk groups 
already there.
— Similarly, the RNX table has the default value for the Route Pattern 
set to 
254. Use change route-pattern 254 to delete any trunk 
groups administered there.
18. Leave the Route Pattern field blank for all dialed strings that you want 
to disallow the calls, such as international and operator calls. 
Any ARS/AAR calls starting with that dialed string will be blocked.
19. For all the route patterns assigned to ARS/AAR Partition 8, use 
change 
route-pattern
 to administer an appropriate FRL (1 through 7) in the FRL 
field. 
Since the FRL on the COR reserved for remote access is 0, the remote 
access caller will always be prompted for an authorization code for outside 
calls.
20. Assign authorization codes for your remote access users that provide the 
lowest possible FRL to match each user’s calling requirements.
See Chapter 3, ‘‘IP security’’
 for additional security measures.
Permanently disabling remote access
For Communication Manager, MultiVantage™ Software, DEFINITY ECS, 
DEFINITY G3, System 85 R2V4n 3.0 and later, and the “n” versions of G1 and 
System 75V3, as an additional step to ensure system security, the Remote 
Access feature can be permanently removed. Permanent removal protects 
against unauthorized remote access usage even if criminals break into the 
maintenance port. See your account representative for information on the “n” 
upgrade.
To permanently disable the Remote Access feature in System 85R2V4n 3.0 and 
later, or G2.2 3.0 and later:
■ Use PROC275 WORD4 FIELD2, and change the value to 1.