Instruction manual
Large business communications systems
5-52 Issue 9 May 2003
This permission is administered on a login basis. Avaya is responsible for
performing the necessary administration for one customer superuser login. If
additional customer logins require access to the system via the INADS port, the
customer superuser login may perform the necessary administration to grant
those permissions.
Forced password aging and administrable logins
DEFINITY G3V3 and later releases provide two features for enhanced
login/password security.
■ The first, Forced Password Aging, is a feature that the superuser
administering the logins may activate. The password for each login can be
aged starting with the date the password was created or changed, and
continuing for a specified number of days, from 1 to 99. A user is notified at
login, seven days before the password expiration date, that his or her
password is about to expire. When the password expires, the user is
required to enter a new password into the system to complete the login
process. Once a non-superuser has changed his/her password, the user
must wait 24 hours to change the password again.
When a login is added or removed, the Security Measurement reports will
not be updated until the next hourly poll, or until a
clear measurements
security-violations
command has been entered.
■ The second feature, Administrable Logins, allows users to define their own
logins/passwords and allows superusers to specify a set of commands for
each login. The system will allow up to 11 customer logins, each of which
can be customized. Each login must be 3 to 6 alphabetic/numeric
characters, or a combination of both. A password must be 4 to 11
characters and contain at least one alphabetic and one numeric symbol.
Passwords can also contain any of the following symbols: ! & * ? ; ’ ^ ( ) , . :
- @ # $ %
NOTE:
The Monitor Security Violation Login tool is used to show the invalid login
used and the date, time, and port that was used.
New shipments of the DEFINITY G3V3 and later are shipped from the factory with
no customer logins and/or passwords defined. One customer superuser password
is administered during installation. The customer must administer additional
logins/passwords as needed. The superuser login has full customer permissions
and can customize any login he or she creates.
On upgrades to the DEFINITY G3V3 or later, customer logins and passwords are
carried forward. Password aging is set to one day, and customers must customize
their logins/passwords following upgrades.