Instruction manual
Large business communications systems
5-52 Issue 9 May 2003
This permission is administered on a login basis. Avaya is responsible for 
performing the necessary administration for one customer superuser login. If 
additional customer logins require access to the system via the INADS port, the 
customer superuser login may perform the necessary administration to grant 
those permissions.
Forced password aging and administrable logins
DEFINITY G3V3 and later releases provide two features for enhanced 
login/password security. 
■ The first, Forced Password Aging, is a feature that the superuser 
administering the logins may activate. The password for each login can be 
aged starting with the date the password was created or changed, and 
continuing for a specified number of days, from 1 to 99. A user is notified at 
login, seven days before the password expiration date, that his or her 
password is about to expire. When the password expires, the user is 
required to enter a new password into the system to complete the login 
process. Once a non-superuser has changed his/her password, the user 
must wait 24 hours to change the password again.
When a login is added or removed, the Security Measurement reports will 
not be updated until the next hourly poll, or until a 
clear measurements 
security-violations
 command has been entered.
■ The second feature, Administrable Logins, allows users to define their own 
logins/passwords and allows superusers to specify a set of commands for 
each login. The system will allow up to 11 customer logins, each of which 
can be customized. Each login must be 3 to 6 alphabetic/numeric 
characters, or a combination of both. A password must be 4 to 11 
characters and contain at least one alphabetic and one numeric symbol. 
Passwords can also contain any of the following symbols: ! & * ? ; ’ ^ ( ) , . : 
- @ # $ % 
NOTE:
The Monitor Security Violation Login tool is used to show the invalid login 
used and the date, time, and port that was used.
New shipments of the DEFINITY G3V3 and later are shipped from the factory with 
no customer logins and/or passwords defined. One customer superuser password 
is administered during installation. The customer must administer additional 
logins/passwords as needed. The superuser login has full customer permissions 
and can customize any login he or she creates.
On upgrades to the DEFINITY G3V3 or later, customer logins and passwords are 
carried forward. Password aging is set to one day, and customers must customize 
their logins/passwords following upgrades.