Instruction manual

Security measures
Issue 9 May 2003
5-47
Require account codes
You can use the Forced Entry of Account Code (FEAC) feature to require callers
to enter an account code (up to 15 digits) before calls to toll numbers are
completed. This option can be specified for an originating station COS (G2 only),
for an outgoing trunk group, or for access to ARS/WCR trunks. If an account code
is not dialed when required, the call is denied. Although there is no verification of
the digits, the digits entered must match the specified length (1 to 15 digits).
For Communication Manager, MultiVantage™ Software, DEFINITY ECS,
DEFINITY G1, G3, and System 75 R1V3:
Use change system-parameters feature to display the Features-Related
System Parameters screen.
Enter 15 in the SMDR/CDR Account Code Length field.
To activate the measure system-wide, enter y in the Force Entry of
Account Codes
field.
To activate the feature on an individual basis, use change cor to display
the Class of Restriction screen.
Enter y in the Force Entry of Account Code field.
Use change station to assign the COR to the appropriate stations.
NOTE:
Station Message Detail Recording (SMDR) and account codes are
only required for toll calls.
For Communication Manager, MultiVantage™ Software, DEFINITY ECS
and DEFINITY G3, use
change toll to display the Toll Analysis screen.
Enter dialed strings that require FEAC, and enter x in the Toll and
SMDR/CDR FEAC fields. For G3, any dialed string, including 7-digit local
numbers, can be identified as “toll.”
For DEFINITY G2 and System 85:
Use PROC010 WORD2 FIELD5 to force account code entry for an
originating station.
Use PROC101 WORD1 FIELD8 to force account code entry for an
outgoing trunk group.
Use PROC312 WORD1 FIELD3 to force account code entry for access
to WCR (G2.2).
Use PROC275 WORD1 FIELD12 to force account code entry for access
to ARS (G2.1 and System 85).
Use PROC275 WORD1 FIELD13 to set the length of account codes
(
1 to 15).