Instruction manual
Security measures
Issue 9 May 2003
5-41
■ Time slot test call — Connects the voice terminal user to a specific time slot 
located on the Time Division Multiplex buses or out-of-service time slots.
■ System tone test call — Connects the voice terminal user to specific 
system tones.
To activate the feature, the Facility Test Calls access code must be assigned. It is 
recommended that the access code be left 
blank except when actually testing 
trunks. (Do not use the default of 197.) The COR of the station user needs to have 
the Facility Access Trunk Test activated on the COR screen.
When properly administered by the customer, the feature enables users to 
minimize the ability of unauthorized persons to gain access to the network. 
However, it is the customer’s responsibility to take the appropriate steps to 
properly implement the features, evaluate and administer the various restriction 
levels, and protect access codes.
!
CAUTION:
In rare instances, unauthorized individuals may connect to the 
telecommunications network through the use of test call features. In such 
cases, applicable tariffs require that the customer pay all network charges 
for traffic.
For Communication Manager, MultiVantage™ Software, DEFINITY ECS, 
DEFINITY G1, G3, and System 75, when the user’s COR allows it, test calls can 
be made to access specific trunks. Do not administer this feature unless you need 
it, and remove it after the test is completed. To remove the Facility Test Calls 
Access Code, use the following procedures.
For Communication Manager, MultiVantage™ Software, DEFINITY ECS, 
DEFINITY G1, G3, and System 75:
■ Enter change feature-access-codes to display the FAC screen.
■ Leave the Facility Test Calls Access Code field blank.
For DEFINITY G2 and System 85, calls over a dial-repeating tie line or designated 
maintenance extension can make trunk verification calls. Use the following 
procedure to disable this feature system-wide.
For DEFINITY G2 and System 85:
■ Use PROC350 WORD2 FIELD1 = 44 to disable the Trunk Verification 
Feature Dial Access Code.
■ Use PROC103 WORD1 FIELD7 to disallow bridge-on for the trunk group.
To allow stations with a specified COR to perform the test, but deny the ability to 
others, use the procedure below: