Specifications

7
2-WIRE
FIRE SLC
ADDRESSABLE
LOOP
4 OR 7 AMP MAIN
POWER SUPPLY
(GEMC-PS24V7A-R or
GEMC-PS24V4A-R)
FIREWOLF-SERIES
LARGE ENCLOSURE (SHOWN)
ADDRESSABLE
SMOKE
DETECTOR
FWC-FSLC-SMK
FWC-FSLC-HEAT
ADDRESSABLE
HEAT
DETECTOR
FWC-FSLC-PULL
ADDRESSABLE
PULL STATION
(Also in Key Reset and Dual Action,
Hex and Keyed models.)
FWC-FSLC-EZM2
DUAL INPUT
MONITOR MODULE
FWC-FSLC-DUCT
DUCT DETECTOR
(Also available,
Remote Annunciator Plate.)
F
I
R
E
W
O
L
F
2 SLC MODULES, max.
Note: The four GEMC-RECV max. is reduced by 1 for each SLC module.
UP TO 126
DEVICES
SMOKE DETECTOR
GEMC-WL-SMK
GEMC-WL-HEAT
HEAT DETECTOR
SINGLE ZONE
TRANSMITTER
WITH TAMPER
GEMC-WL-WD2
Single Fire
initiating
N/O device
GEMC-NAC7
NAC EXTENDER
(5, MAX.)
GEMC-F8ZCPIM
8 Fire Zone Expander
}
8 ZONES OF
CONVENTIONAL 2-WIRE SMOKES
PULL STATIONS AND/OR HEAT DETECTORS
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
}
• 4 ON-BOARD NAC
CIRCUITS (CLASS B)
(NOT SHOWN)
-- or --
• 2 ON-BOARD NAC
CIRCUITS (CLASS A)
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
FIRE BUS DEVICES
GEMC-EZM8
8 ZONE
CONVENTIONAL
ZONE EXPANSION
MODULE
GEMC-OUT8
8 ZONE OUTPUT
REMOTE RELAY
MODULE
GEMC-FPRINT
PRINTER
MODULE
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
FWC-FSLC-EZM1
FAST RESPONSE
MONITOR MODULE
FWC-FSLC-RM2
DUAL RELAY
MODULE
FWC-FSLC-SOM1
SUPERVISED
OUTPUT MODULE
FWC-FSLC-CZM
CONVENTIONAL
ZONE MODULE
FWC-FSLC-ISO
SHORT CIRCUIT
ISOLATOR
FWC-FSLC-SMK6B
(6" BASE ONLY)
FIRE KEYPAD
GEMC-FK1
(4, MAX.)
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
}
• 4 ON-BOARD NAC
CIRCUITS (CLASS B) (SHOWN)
-- or --
• 2 ON-BOAR D NAC
CIRCUITS (CLASS A)
MUST BE ALL
WHEELOCK OR ALL
SYSTEM SENSOR
FIREWOLF FIRE SYSTEMS & COMPONENTS
MOTHERBOARD
INTERNET REPORTING
MODULE
FI
R
E
K
E
Y
P
A
D
GE
M
C
-
FK
1
GEMC-12V2APS-CF
12V AUX POWER
SUPPLY
F
W
C
-
F
S
L
C
-D
U
C
T
D
U
C
T
D
E
T
E
C
T
O
R
(
Also available,
t
A
it
Pl
F
F
F
F
F
F
F
F
F
F
F
I
I
I
F
F
F
F
F
F
F
F
F
F
R
R
FF
E
R
R
W
W
W
W
W
W
W
W
W
W
W
O
O
O
O
O
O
O
O
O
O
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
L
L
L
L
L
L
L
L
L
L
L
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
F
F
F
F
F
F
F
F
F
L
L
L
L
L
L
L
L
L
L
L
L
W
C
-
F
SLC-P
U
AD
D
R
ES
S
A
B
L
E
F
W
C
-
F
S
L
C
-
CZ
M
C
O
NV
E
N
T
I
O
N
A
L
Z
O
N
E
M
O
D
U
L
E
FW
C
-
F
S
L
C
-S
O
M
S
U
P
E
R
V
I
S
E
D
O
U
T
P
U
T
M
O
D
U
L
E
F
W
C
-
F
S
L
C
-
R
M
2
D
U
A
L
R
E
L
A
Y
A
A
M
O
D
U
L
E
F
W
C
-F
S
L
C
-
I
SO
S
H
O
R
T
C
I
R
C
U
I
T
I
S
O
L
A
T
A
A
O
R
F
W
C
-
F
S
L
C
-
EZM
D
U
A
L
I
N
P
U
T
M
O
N
I
T
O
R
M
O
D
U
L
E
W
C
-
FSLC-
H
E
A
A
D
D
R
E
S
S
A
B
L
E
H
E
A
T
T
AD
D
R
E
S
S
A
B
L
E
S
M
O
K
E
E
W
C
-
F
S
L
C
-
SM
K
N
GEMC-RM3008
OUTPUT
MODULE
8
L
O
N
SM
R
G
E
M
C
-
W
L
-
H
E
A
T
H
E
A
T
DE
T
E
C
T
O
R
G
WD
2
G
E
M
C
-
W
L
-
S
M
K
MO
K
E
DE
T
E
C
T
O
R
G
E
M
C
W
L
H
E
A
T
S
I
N
G
L
E
Z
O
S
i
ng
i
n
i
N
/
O
G
E
M
C
-
W
L
-
W
(4
MAX
)
GEMC-RECV
WIRELESS
RECEIVER
Addressable Fire Peripherals
GEMC-FW-SLC Addressable SLC Fire Module, supports up to 128
addressable SLC fire devices, below. (Connect up to 2/panel.)
FWC-FSLC-SMK Addressable Analog Smoke Photoelectric, head**
FWC-FSLC-HEAT Addressable Analog Heat, 135 degrees, head**
FWC-FSLC-DUCT Addressable Duct smoke detector, photoelectric.
FWC-FSLC-DUCTRA Remote Indicator Plate with LED indicator & key
reset
FWC-FSLC-EZM1 Addressable SLC 1-input conventional module, similar
usage to above.
FWC-FSLC-EZM2 Addressable 2-zone conventional expansion module.
Uses one address on SLC loop, but yields 2 independent contact
monitoring circuits for pull stations, waterflow and other dry contact alarm
initiating devices.
FWC-FSLC-CZM Addressable single module, for dry contacts
FWC-FSLC-RM2 Addressable 2-output module (uses 1 SLC address)
FWC-FSLC-ISO Addressable Short Circuit module (Optional for special
apps., meets Class A, Style 7 loop reqts.)
FWC-FSLC-SOM1 Addressable Fire supervised output module (ex.
Elevator recall, HVAC shutdown, additional
FWC-FSLC-PULL Addressable Pull Station
FWC-FSLC-PULLK Addressable Pull Station, Key Reset
FWC-FSLC-PULL2 Addressable Dual Action Pull Station
FWC-FSLC-PULL2K Addressable Dual Action Pull Station, Key Reset
FWC-FSLC-PROG2 Tool for address programming SLC devices
FWC-FSLC-SMK6B **Smoke/Heat, 6” base required for FWC-FSLC-SMK
& -HEAT
Conventional Fire Peripherals
GEMC-FK1 LCD Fire Red Keypad (Menu-driven operation, functionality
for Reset, Acknowledge, Silence (with disable).
GEMC-F8ZCPIM Conventional 8-zone 2-wire fire input mod.
GEMC-EZM8 8-pt expander
GEMC-NL-MOD Internet Reporting Module
Output Options for Fire Systems
GEMC- FPRINT Parallel printer module
GEMC-RM3008 8 Form C Relay Output Mod
GEMC-RS232 RS232 Adapter for serial output
GEMC-OUT8 PGM 8-Output Module
New Options:
FN-CTM City Tie Module Option
GEMC-KEYSWKT Keyswirch Kit
GEMC-LOCK-CAT30 Keyed-Alike pull stations & panel enclosures
New Commercial Fire
Features:
• New! Fire Quick-Start
System Programming &
EZ-Maintenance Modes
• Horn/Strobe simultaneous
silence
• 1-Button Supplemental
Reset
• 4-Cycle coded cadence
• Fire Function global keypad
unlock