Specifications

2-WIRE
FIRE SLC
ADDRESSABLE
LOOP
4 OR 7 AMP MAIN
POWER SUPPLY
(GEMC-PS24V7A-R or
GEMC-PS24V4A-R)
ADDRESSABLE
SMOKE
DETECTOR
FWC-FSLC-SMK
FWC-FSLC-HEAT
ADDRESSABLE
HEAT
DETECTOR
FWC-FSLC-PULL
ADDRESSABLE
PULL STATION
(Also in Key Reset and Dual Action,
Hex and Keyed models.)
FWC-FSLC-EZM2
DUAL INPUT
MONITOR MODULE
FWC-FSLC-DUCT
DUCT DETECTOR
(Also available,
Remote Annunciator Plate.)
F
I
R
E
W
O
L
F
UP TO 126
DEVICES
SMOKE DETECTOR
GEMC-WL-SMK
GEMC-WL-HEAT
HEAT DETECTOR
SINGLE ZONE
TRANSMITTER
WITH TAMPER
GEMC-WL-WD2
Single Fire
initiating
N/O device
GEMC-NAC7
NAC EXTENDER
(5, MAX.)
GEMC-F8ZCPIM
8 Fire Zone Expander
}
8 ZONES OF
CONVENTIONAL 2-WIRE SMOKES
PULL STATIONS AND/OR HEAT DETECTORS
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
}
• 4 ON-BOARD NAC
CIRCUITS (CLASS B)
(NOT SHOWN)
-- or --
• 2 ON-BOARD NAC
CIRCUITS (CLASS A)
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
EOLR
2.2K
S
+
+
–
–
SMOKE
2-WIRE
S
+
+
–
–
SMOKE
2-WIRE
FIRE BUS DEVICES
GEMC-EZM8
8 ZONE
CONVENTIONAL
ZONE EXPANSION
MODULE
GEMC-OUT8
8 ZONE OUTPUT
REMOTE RELAY
MODULE
GEMC-FPRINT
PRINTER
MODULE
HORN
STROBE
MUST BE
ALL
WHEELOCK
OR ALL
SYSTEM
SENSOR
EOLR
2.2K
STROBE
HORN
HORN
STROBE
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
FWC-FSLC-EZM1
FAST RESPONSE
MONITOR MODULE
FWC-FSLC-RM2
DUAL RELAY
MODULE
FWC-FSLC-SOM1
SUPERVISED
OUTPUT MODULE
FWC-FSLC-CZM
CONVENTIONAL
ZONE MODULE
FWC-FSLC-ISO
SHORT CIRCUIT
ISOLATOR
FWC-FSLC-SMK6B
(6" BASE ONLY)
FIRE KEYPAD
GEMC-FK1
(4, MAX.)
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
EOLR
2.2K
HORN
EOLR
2.2K
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
STROBE
HORN
HORN
STROBE
}
• 4 ON-BOARD NAC
CIRCUITS (CLASS B) (SHOWN)
-- or --
• 2 ON-BOARD NAC
CIRCUITS (CLASS A)
MUST BE ALL
WHEELOCK OR ALL
SYSTEM SENSOR
INTERNET REPORTING
MODULE
FI
R
E
K
E
Y
P
A
D
G
E
M
C
-FK
1
GEMC-12V2APS-CF
12V AUX POWER
SUPPLY
FW
C
-
F
S
L
C
-D
U
C
T
D
U
C
T
D
E
T
E
C
T
O
R
(
Also available,
tA it Pl
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
I
I
I
F
F
F
F
R
R
FF
E
R
R
W
W
W
W
W
W
W
W
W
W
W
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
L
L
L
L
L
L
L
L
L
L
L
O
O
O
O
O
O
O
O
O
O
O
O
O
O
F
F
F
F
F
F
F
F
F
F
F
F
F
F
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
W
C
-
FS
L
C
-P
U
AD
D
R
ES
S
A
B
L
E
F
W
C
-
F
S
L
C
-C
Z
M
C
O
NV
E
N
T
I
O
N
A
L
Z
O
N
E
M
O
D
U
L
E
FW
C
-
F
S
L
C
-S
O
M
S
U
P
E
R
V
I
S
E
D
O
U
T
P
U
T
M
O
D
U
L
E
F
W
C
-
F
S
L
C
-
R
M
2
D
U
A
L
R
E
L
A
Y
A
A
M
O
D
U
L
E
F
W
C
-F
S
L
C
-
I
SO
S
H
O
R
T
C
I
R
C
U
I
T
I
S
O
L
A
T
A
A
O
R
F
W
C
-
F
S
L
C
-
EZM
D
U
AL
I
N
P
U
T
M
O
N
I
T
O
R
M
O
D
U
L
E
W
C
-
F
S
L
C
-
H
E
A
A
D
D
R
E
S
S
A
B
L
E
H
E
A
T
T
A
D
D
R
E
S
S
A
B
L
E
S
M
O
K
E
E
W
C-
F
S
L
C
-
S
M
K
N
GEMC-RM3008
OUTPUT
MODULE
8
L
O
N
SM
R
G
E
M
C
-
W
L
-
H
E
A
T
H
E
A
T
DE
T
E
C
T
O
R
G
WD
2
G
E
M
C
-
W
L
-
S
M
K
MO
KE
DE
T
E
C
T
O
R
G
E
M
C
W
L
H
E
A
T
SI
N
G
L
E
Z
O
S
i
ng
i
n
i
N
/
O
G
E
M
C
-
W
L
-
W
(
4MA
X)
GEMC-RECV
WIRELESS
RECEIVER
GEMINI C-SERIES
MOTHERBOARD
2-WIRE
BURG SLC
ADDRESSABLE
LOOP
GEMINI C-SERIES COMMERCIAL
COMBINATION CONTROL PANEL
UP TO 126
DEVICES
DUAL TECH PIR
GEMC-BSLC-DT
SINGLE RELAY
MODULE
GEMC-BSLC-RLY
GEMC-BM or
GEMC-BM/PS
BURGLARY
MODULE
PIR
GEMC-WL-PIR
DUAL TECH PIR
GEMC-WL-DT
GLASS BREAK
GEMC-WL-GB
GEMC-WL-WD2*
WINDOW / DOOR
TRANSMITTER
WITH TAMPER
KEYFOB
GEM-KEYF
BURGLARY BUS DEVICES
GEMC-RECV
WIRELESS
RECEIVER
SINGLE POINT
CONVENTIONAL
ZONE
EXPANDER
GEMC-BSLC-1PT
GEMC-BSLC-4PT
4 POINT
CONVENTIONAL
ZONE
EXPANDER
(4, MAX.)
BURGLARY
KEYPAD
(15, MAX.)
GEMC-BK1
PIR
GEMC-BSLC-PIR
GEM-ACM1D
ACCESS
CONTROL
MODULE
(4, MAX.)
GEM-2D
SECOND DOOR
ACCESS CONTROL
ACCESSORY
ACCESS
CONTROL
DEVICES
(ONE FOR EACH
GEM-ACM1D)
GEMC-WL-WD
LOW PROFILE
WINDOW / DOOR
TRANSMITTER
GEMC-EZM8
8 ZONE
CONVENTIONAL
ZONE EXPANSION
MODULE
(31, MAX.)
GEMC-OUT8
8 ZONE OUTPUT
REMOTE RELAY
MODULE
(11, MAX.)
GEMC-RM3008
OUTPUT
MODULE
(11, MAX.)
†Residential Burglary when both loops are used
Single Commercial Burglary Supervised Loop and Integral Magnetic Contact
2 SLC MODULES, max.
• Two Fire or
• Two Burglary or
• One Fire and one Burglary
Note: The four GEMC-RECV max. is reduced by 1 for each SLC module.
GEMC-RS232
SERIAL OUTPUT
CONVERTER
GEMC-12V2APS-R
12V AUX POWER
SUPPLY
B
U
R
G
L
A
R
Y
R
R
GEMC-BSLC Burg SLC Mod. and
GEMC-FW-SLC Fire SCL Mod
Mount beneath motherboard
Configuration Diagram
5