User`s manual

Installation and Wiring
GFK-1742A Chapter 3 Installing and Wiring the DSM314 3-17
3
Figure 3-9. Auxiliary Terminal Board Assembly Side View
The following procedure should be used if you wish to mount the auxiliary terminal board directly
to a panel instead of on a DIN-rail. Remember to save all removed parts for possible later
conversion back to DIN-rail mounting.
1
.
Using a small bladed Phillips screwdriver, carefully remove the two screws holding one UM-
45 SEFE side element with foot to the UM 45 Profil PCB carrier. Save this part for possible
future use in converting the terminal board back to its DIN-rail mounting configuration.
2
.
Attach one UMK 45-SES side element to the PCB carrier in place of the side removed in step
1 above, again using the two screws. Be careful to not over tighten the screws.
3
.
Insert one UMK-BF mounting ear into the appropriate two holes in the side element. Note
that the mounting ear has a recessed hole for later inserting a (user supplied) mounting screw.
The recessed hole should face upwards to accommodate the mounting screw.
4
.
Repeat steps 1-3 above for the other side of the terminal board.