User`s manual

16-50 Motion Mate DSM314 for Series 90-30 PLCs User's Manual
January 2001 GFK-1742A
16
Figure 16-40. RVTExample Screen Second Dwell
When the master axis reaches 50000 (47500 +2500), the CAM command will exit, the slave axis
will decelerate at the programmed acceleration rate and come to a halt, and both axes will return to
zero.
Details on the DSM314s %AI, %AQ, %I, and %Q memory are found in Chapter 5.
Axis 1 Commanded
Position
Axis 1 Actual
Position
Axis 2 Commanded
Position
Axis 2 Actual
Position