User`s manual

15-2 Motion Mate DSM314 for Series 90-30 PLCs User's Manual
January 2001 GFK-1742A
15
Before creating a file, check the Workbench default settings to make sure that Series 90-30 is
the default PLC. To do this, click Tools on the Menu bar (see Figure 15-4), then click the
Options selection. The Options dialog box will appear, as shown next:
Figure 15-2. Checking the VersaPro Default Settings in the Tools/Options Dialog Box
Make sure Series 90-30 is shown in the Default Hardware Configuration box, then click the
OK button.
To open a folder, click File on the Menu bar, then either click Open Folder to open an existing
one, or click New Folder to create a new one. You can also import an existing Series 90-30
folder that was originally created in Logicmaster or Control. See the Folder Operations
section of Chapter 2 in the VersaPro Users Guide for details. For this example, well click
New Folder. A New Folder Wizard dialog box will appear as shown in the next figure.
Figure 15-3. The New Folder Wizard Dialog Box
Enter a name for your folder. Although you can use up to 255 characters to name the folder,
only the last 7 characters will be used as the folder name in the PLC. These last 7 characters of
the Folder Name are called the Folder Nickname. This being the case, you may wish to
carefully name your folder so that its nickname is meaningful. For example, if your Folder