11 Error messages
The following error messages were generated by the controller and displayed on the
screen:
Error message Cause Solution
“Sensor” error The attached sensor was - Connect sensor
was not recognised or - Replace sensor
is faulty..
“Too Hot” error The temperature sensor has Open oven and allow to cool down
detected that the tempera-
ture is too high to start a
new soldering process.
“Oven” error The temperature in the oven - Oven switched on?
has not reached the defined - Oven connected?
preset value. - Oven door closed?
- Power setting too low?
- Minimum temperature increase
incorrectly set
“Learn” error The oven characteristics have Start a learn procedure for the oven
not yet been learned.
12 Maintenance and disposal
The reflow controller is maintenance-free.
The mains fuse should only be changed by a qualified specialist and the replacement
fuse should have the same technical specifications. The use of repaired fuses and the
practice of bridging fuses are not permitted.
Repairs should only be carried out by an authorised specialist.
Used electronic devices are recyclable and should not be disposed of with household
refuse.
The device must be disposed of at the end of its life according to the appropriate legal
guidelines.
These instructions represent an accurate technical description at the time of going to press.
Subsequent changes in technology or configuration are reserved.