FAQ

A. To test the GFCI plug, insert it into a grounding type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your local Bestway Customer Service.
NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s Inlet and Outlet valves are fully
covered by water before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR
SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Stop water flowing to the Filter Pump refer to pool’s manual.
3) Unscrew the Filter Cap Retainer and remove the Filter Cap.
4)
Clean the Filter Cartridge with a garden hose.If filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
6) Check that the Filter Cap Seal is in place.
7) Replace the Filter Cap and screw the Filter Cap Retainer into position.
8) Open the Valve A and B.
9) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT:
To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons we
suggest replacing the Filter Cartridge with a new one every two weeks.
PUMP STORAGE
1) Unplug the Filter Pump.
2) Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40
O
C (39.2-104
O
F)
7) Drain the pool according to the Pool Owner’s Manual.
Pump Warranty
For information concerning pump warranty please visit our website at: www.bestwaycorp.com
RESET
TEST
RESET
TEST
RESET
TEST
A B
C
D
GFCI Test