HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at .01 in. static pressure, based
on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
55 22
LIMITED
WARRANTY
YEARS ON PARTS YEARS ON LABOR
/
HVI PERFORMANCE
SONES
Normal Medium* High* Boost
0.5 4.0 7.5 11.5
CFM
Normal Medium* High*
Boost
0.25 in. w.g.
Boost
0.1 in. w.g.
290 615 880 990 1070
* Where noted performance rating is not HVI certified but was established in accordance
with HVI Standardized test procedure.
AIRFLOW PERFORMANCE
0
0.5
1
1.5
2
2.5
400200600 8001000 12
00
Static pressure
(in.w.g.)
Airflow (cfm)
Vertical High Speed – 10" round
Vertical High Speed – 10" round
HOOD SIZES*
Internal Blower – Depth: 24''
48" WPB9IQT48SB
* For exact dimensions, please refer to the technical drawing of each model.
FEATURES
Finish Brushed Stainless Steel (Grade 430)
Lighting Type Halogen, T4, G9, 25W
Number of Lamps 4
Lighting Levels 2
Lighting Lamps Inclu ded Yes
Control Type 3‑speed Plus Boost Electronic
Pushbutton with Display
Control Features Heat Sentry™, Delay Off, Filter
Clean Reminder
Remote Control Optional ACR3
Filter Type Hi‑Flow Baffle
Non-ducted Capability No
HOOD BLOWER INCLUDED WPB9IQ
Internal iQ12
Max Blower CFM* 1500
ACCESSORIES
10'–11' Flue Extension AEWPB9SBN
(ducted and non‑ducted)
Universal MUA Damper MD6TU, MD8TU, MD10TU
(Requires Fresh Air Inlet)
Fresh Air Inlet 641FA, 643FA, 610FA
INSTALLATION REQUIREMENTS
Amps @ 120V: Internal Blower 8.4
Amps @ 120V: External Blower 7.0 Max
Electrical Connection Direct Wire
Duct Size: Internal Blower 10"
Duct Size: External Blower 10"
Duct Direction Vertical
Backdraft Damper Included
*MAX Blower CFM indicates the performance of the hood blower in open air.
Installation height above the cookin g surface: 24"–36"
99045834E 10/21
WPB9 Series
Telescopic flue for 8'–9' ceiling is standard.
Optional flue extensions for 10'–11' ceiling.
Upper flue can be reversed to hide louvers in some
applications depending on installation heights.
3-1/8
min. 34-1/2 - max. 45-1/4
28-1/2
20-1/2
15
17-1/8
24