Specification Sheet

CHIMN EY
BESTRANGEHOODS.COM
USA 800-558-1711
BESTRANGEHOODS.CA
CANADA 800-567-3855
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at .01 in. static pressure, based
on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
55 22
LIMITED
WARRANTY
YEARS ON PARTS YEARS ON LABOR
/
HOOD SIZES*
Internal Blower, Single - Depth: 19-11/16"
30" WCN1306SS 36" WCN1366SS
* For exact dimensions, please refer to the technical drawing of each model.
FEATURES
Finish Brushed Stainless Steel
(Grade430)
Lighting Type LED Modules (6W per module,
color temp 3000K) 500 LUX
Number of Modules 2
Lighting Levels 3
Lighting Modules Included Yes
Control Type 4-speed Capacitive Control
Control Features Delay-off
Remote Control No
Filter Type Mesh with Decorative Stainless
Steel Plate
Non-ducted Capability Yes
HOOD BLOWER INCLUDED WCN1
Internal
Max Blower CFM* 685
ACCESSORIES
10'–11' Flue extension AEWCN1SS
(ducted—non-ducted)
Recirculation Kit ANKWCN1
Baffles Filters (set of 2) AFBWCN1
Universal MUA Damper MD6TU, MD8TU, MD10TU
(Requires Fresh Air Inlet)
Fresh Air Inlet 641FA, 643FA, 610FA
INSTALLATION REQUIREMENTS
Amps @ 120V: Internal Blower 3.9
Electrical Connection Plug In
Duct Size: Internal Blower 8"
Duct Direction Vertical
Backdraft Damper Included
*MAX Blower CFM indicates the performance of the hood blower in open air.
HVI PERFORMANCE
INTERNAL BLOWER – WCN1
SONES
Speed 1 Speed 2* Speed 3* Speed 4
0.9 2.5 4.0 11.0
CFM
Speed 1 Speed 2* Speed 3*
Speed 4
0.25 in. w.g.
Speed 4
0.1 in. w.g.
160 240 300 580 600
* Where noted performance rating is not HVI certified but was established in accordance
with HVI Standardized test procedure.
AIRFLOW PERFORMANCE
0
0.5
1
1.5
2
2.5
300100200 400500 60
0700
Static pressure
(in.w.g.)
Airflow
(cfm)
Vertical High Speed – 8" round
Vertical High Speed – 8" round
Installation height above the cooking surface: 24"–30"
Telescopic flue accommodates ceiling heights from 8' to 9'. Flue extension
for higher ceilings is also available. Upper flue can be reversed to hide
louvers in some applications depending on installation heights.
If needed, ask a
recommended
installer to limit
discharge to 300
or 400 CFM.
99046207C10/21
WCN1 Series