Specification Sheet

CHIMN EY
BESTRANGEHOODS.COM
USA 800-558-1711
BESTRANGEHOODS.CA
CANADA 800-567-3855
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at .01 in. static pressure, based
on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
55 22
LIMITED
WARRANTY
YEARS ON PARTS YEARS ON LABOR
/
99045177C 10/21
HOOD SIZES*
Internal Blower, Single – Depth 17-11/16''
36" WC45IQ90SB
External (blower sold separately) – Depth 17-11/16''
36" WC45E90SB
* For exact dimensions, please refer to the technical drawing of each model.
FEATURES
Finish Brushed Stainless Steel (Grade 430)
Lighting Type LED 6W
Number of Lamps 2
Lighting Levels 1
Lighting Lamps Included Yes
Control Type 4-speed Electronic “IR” Infrared
Control Features Heat Sentry™, Delay Off,
Filter Clean Reminder
Remote Control Optional ACR3
Filter Type Stainless Steel with Mesh Grease
Non-ducted Capability Yes
HOOD BLOWER INCLUDED WC45IQ
Internal iQ6
Max Blower CFM* 800
HOOD BLOWER OPTIONS (blowers sold separately)
Refer to external blower's specification sheets for HVI performance
(sones and CFM).
External In-line ILB3 ILB6 ILB9 ILB11
Max Blower CFM* 300 675 900 1500
External Exterior EB6 EB9 EB12 EB15
Max Blower CFM* 665 890 1300 1650
ACCESSORIES
10'–11' Flue Extension AEWC345IQSBN
Non-Duct Kit ANKWC345
Non-Duct Filter AFCWC345
Universal MUA Damper MD6TU, MD8TU, MD10TU
(Requires Fresh Air Inlet)
Fresh Air Inlet 641FA, 643FA, 610FA
INSTALLATION REQUIREMENTS
Amps @ 120V: Internal Blower 4.0
Amps @ 120V: External Blower 7.0 Max
Electrical Connection Plug In
Duct Size: Internal Blower 8"
Duct Size: External Blower 8"
Duct Direction Vertical
Backdraft Damper Included
*MAX Blower CFM indicates the performance of the hood blower in open air.
Installation height above the cooking surface: 24"–30"
HVI PERFORMANCE
INTERNAL BLOWER – WC45IQ
SONES
Normal Medium* High* Boost
<0.3 1.6 4.7 8.5
CFM
Normal Medium* High*
Boost
0.25 in. w.g.
Boost
0.1 in. w.g.
110 225 360 465 500
* Where noted performance rating is not HVI certified but was established in accordance
with HVI Standardized test procedure.
AIRFLOW PERFORMANCE
0
0.5
1
1.5
2
2.5
200100300 400500 60
0
Static pressure
(in.w.g.)
Airflow
(cfm)
Vertical High Speed – 8'' round
Vertical High Speed – 8'' round
WC45 Series
Telescopic flue for 8'–9' ceiling is standard.
Optional flue extensions for 10'–11' ceiling.
Upper flue can be reversed to hide louvers in some
applications depending on installation heights.
If needed, ask a recommended installer to limit discharge to 300 or 400 CFM.
17-11/16
1-5/8
min. 27-7/8 - max. 47-7/8
11-15/16
10-7/8
30-3/4
35-7/16
(90 cm)
24-13/16