Technical Specifications

WC35IQ SERIES WIRING
120 VOLT 60 HZ
GROUNDED WALL
OUTLET OFFSET
FROM DUCT CENTER
LINE . (STAY WITHIN
5½” DIMENSION)
WC35IQ SERIES
MOUNTING
a. Minimum hood distance above cook top must not be less than 24”. A maximun of 30” above
cook top is highly recommended for best capture of cooking impurities. Distances over 30” are
at the installer and user’s discretion; and if ceiling height and flue length permit.
b. Requires optional 10-ft. to 11-ft. flue extension, ducted model AEWC345IQSB or non-ducted
model AEWC345IQSBN.
* Non-duct slots will be exposed.
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note below)
30”
MOUNTING BRACKET TOP HOLE LOCATION ABOVE 36” HIGH COOK TOP
CEILING
HEIGHT
8 FEET
24” 25” 26” 27” 28” 29”
WOOD CROSS
SUPPORT BEHIND
DRYWALL
DRYWALL
DUCTED
NON-DUCTED
DUCT
METHOD
FRAMING
BEHIND WOOD
CROSS SUPPORT
CENTERLINE
3-1/2”
3-1/2”
2-3/16”
9 FEET
DUCTED OR
NON-DUCTED
10 FEET
(see note b.)
--- ---
40” 41” 42” 43” 44” 45” 46”
19½”
to
20½”
5½”
11”
CENTERLINE
OF HOOD
25
1
/
8
18
5
/
8
40” 41” 42” 43” 44” 45” 46”
40” * 41” * 42” 43” 44” 45” 46”
40” 41” 42” 43” 44” 45” 46”
11 FEET
(see note b.)
42” 43” 44” 45” 46”