Installation manual

- 8 -
INSTALL MOUNTING
BRACKETS
DUCTED and NON-DUCTED HOODS
1. Construct wood wall framing that
is flush with interior surface of wall
studs. Fig. 6.
Make sure:
a) the framing is centered over in-
stallation location.
b) the height of the framing will al-
low the mounting brackets to be
secured to the framing within the
dimensions shown.
2. After wall surface is finished, se-
cure each mounting bracket to fram-
ing with (2) 4.8 x 38 mm mounting
screws. See chart below for mounting
bracket location.
Note : Minimum hood distance above cook top must not be less than 24”. A maximum
of 30” above cook top is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and user’s discretion; and if ceiling height
and flue length permit.
FIG. 6
FRAMING BEHIND
WOOD CROSS
SUPPORT
WOOD CROSS
SUPPORT BEHIND
DRYWALL
DRYWALL
12-1/2”
2-3/16”
CEILING
HEIGHT
DUCT
METHOD
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note blow)
DUCTED OR
NON-DUCTED
INSTALLATIONS WITH FLUE
24” 25” 26” 27” 28” 29” 30”
8 FEET
35” 36” 37”
CEILING
HEIGHT
DUCT
METHOD
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note blow)
NON-DUCTED
NON-DUCTED INSTALLATIONS WITHOUT FLUE (WITH BLADE GUARD ONLY)
24” 25” 26” 27” 28” 29” 30”
8 or
9 FEET
35” 36” 37” 38” 39” 40” 41”
9 FEET
DUCTED OR
NON-DUCTED
35” 36” 37” 38” 39” 40” 41”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
or