Installation Guide
7
5. REMOVE THE PAN
Using a Phillips no. 2 screwdriver, remove the screws retaining the pan (shaded part
on illustration at right) to the hood. Remove the pan and set aside.
8. PREPARE THE CABINET (DUCTED INSTALLATIONS ONLY)
For cabinets with recessed bottom, attach two wood filler strips cut to length (not included), on each side, as shown below. See table below
for wood filler strips location.
HOOD WIDTH
CENTER OF WOOD
STRIP LOCATION (A)
30" 13
3
8"
36" 16
3
8"
42" 19
3
8"
48" 22
3
8"
HD0208
L
C
AA
HD0114
Cut-out the openings for duct (A) and house wiring (120 VAC) (B) according to the blower option chosen. See figures below.
HD0110A
L
C
CABINET BOTTOM
9
5
8”
5”
HOOD WITH IN-LINE OR EXTERIOR BLOWER
3¼”
4
5
8”
B
A
Ø 10”
9
7
8”
5
5
8”
L
C
CABINET BOTTOM
8¾”
4”
HOOD WITH INTERNAL BLOWER
3¼”
4
5
8”
B
A
Ø 8”
98”
4
5
8”
7. INSTALL THE NON-DUCT KIT FLUE ANKUP27M SERIES (NON-DUCTED INSTALLATION ONLY)
6. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 8, 10 to 13, then 15 and up of the present manual.