UP26M Installation Manual SV21517 rev. 03
3
HL0220
- UP26M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
MODEL 647
(7” ROUND WALL CAP)
MODEL 634 OR 644
(ROOF CAP)
8” R
OUND
STANDARD
DUCT
MODEL 413
TRANSITION
(3¼” X 10” TO 8”)
M
ODEL 459 TRANSITION
(3¼” X 14” TO 8”)
M
ODEL 643
(8” ROUND WALL CAP)
A
DAPTER/DAMPER
3¼” X 14”
(SUPPLIED WITH P8 BLOWER)
UP26M HOOD
MODEL 412
TRANSITION
(3¼” X 10” TO 7”)
M
ODEL 407
(7” ROUND—
2 FT SECTIONS)
M
ODEL 415
7” ROUND
ADJUSTABLE
ELBOW
(OPTIONAL)
8” ROUND ADJUSTABLE
ELBOW (OPTIONAL)
STANDARD
3¼” X 14” DUCT
FLOW DEVIATOR
(VERTICAL EXHAUST ONLY)
(SUPPLIED WITH P5 AND P8 BLOWERS)
A
DAPTER/DAMPER 3¼” X 10”
(SUPPLIED WITH P5 AND P8
BLOWERS)
R
OUGH-IN KIT
(SUPPLIED WITH P5 AND P8 BLOWERS)
MODEL P5
SINGLE-BLOWER (500 CFM)
BACKSPLASH (RMP SERIES)
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES. OPTIONAL)
M
ODEL P8 DUAL-BLOWER (900 CFM)
FOR USE WITH 36” HOODS OR WIDER
NOTE: The dual blower P8 must
be installed with 3¼” x 14”
duct. If it is impossible to
connect the dual blower P8
to a 3¼” x 14” duct, use a
3¼” x 10” duct. In that case,
the blower performance will
be decreased by 25%.
STANDARD
3¼” X 10”
DUCT
MODEL 634 OR 644
(ROOF CAP)
UP26M HOOD
MODEL 438
8” ROUND ADAPTER/DAMPER
(SUPPLIED WITH P3, P6 AND
IQ6 BLOWERS)
ROUGH-IN KIT
(SUPPLIED WITH P3, P6 AND IQ6 BLOWERS)
MODELS P3 (300 CFM), P6 (600 CFM)
OR IQ6 (600 CFM) SINGLE BLOWER
MODEL 643
(8” ROUND WALL CAP)
MODEL 408
8” ROUND
STANDARD DUCT
MODEL 432
8” ROUND ADJUSTABLE
ELBOW (OPTIONAL)