Installation Guide
- 11 -
WIRING
CAUTION: All electrical wiring should
be done by a qualified person (s) in
accordance with all applicable codes
and standards. This range hood must
be properly grounded.
Do not turn power on at service panel
until all wires have been connected.
Blower connection at hood:
1. Run 2-wire plus ground power cable
from the exterior blower to the hood’s
wiring box marked “motor connec-
tion”.
2. Remove the cover from the wiring
box.
3. Feed 6” of cable through the knock-
out opening and secure the cable to
the wiring box with an appropriate
connector.
4. Make electrical connections at the
hood. Connect white-to-white, red-
to-black and green-to-ground.
5. Replace the wiring box cover and
screws. Make sure wires are not
pinched between the cover and box.
Exterior blower connection:
1. Make electrical connections at the ex-
terior blower (see instructions pro-
vided with the exterior blower).
Power connection at hood:
1. Run 120 VAC electrical power cable
to the hood wiring box marked
“120VAC input”.
2. Remove the cover from the wiring
box.
3. Feed 6” of cable through the knock-
out opening and secure the cable to
the wiring box with an appropriate
connector.
4. Make electrical connections at the hood. Connect white-to-white, black-to-
black and green-to-ground.
5. Replace the wiring box cover and screws. Make sure wires are not pinched
between the cover and box.
BLOWER CONNECTION AT HOOD
EXTERIOR BLOWER
CONNECT: WHITE-TO-WHITE
RED-TO-BLACK
GREEN-TO-GROUND
BOX MARKED
“MOTOR CONNECTION”
120 VOLT 60 Hz LINE IN
BOX MARKED
“120 VAC INPUT”
CONNECT:
WHITE-TO-WHITE
BLACK-TO-BLACK
GREEN-TO-GROUND
POWER CONNECTION AT HOOD