SMD6 Installation Guide 99044540E
MODELS SMD6 • SMD8
Page 3
Damper and outside air duct connected directly to a ceiling, floor, or wall register.
INTERIOR WALL
WALL
REGISTER
REGISTER BOX ADAPTED
WITH SLIDE-IN FILTER (optional)
MOTORIZED DAMPER
WALL CAP WITH
BIRD SCREEN
INSULATED OUTSIDE
AIR DUCT (slope toward wall cap)
EXTERIOR WALL
VENTILATION AIR INTAKE
(locate away from pollutant sources)
INSTALL THE DAMPER
OUTSIDE AIR
TO CENTRAL SYSTEM
RETURN AIR OR INTERIOR
WALL REGISTER
DAMPER FLAP (Install in
vertical position shown.)
AIR FLOW AIR FLOW
CONNECT TO
24V TRANSFORMER
SET SCREW
WHT
WHT
LINE
VOLTAGE
120 VAC
60 HZ
BLK
24V
BLK
WHT
MAKE-UP AIR DAMPER
24V
TRANSFORMER
(included)
GRD
BLK
WHT
RED
LINKLOGIC
RELAY
GRD
position. The set screw can be used to adjust the damper opening
- thereby balancing the inside and outside air pressure when the
range hood exhausts at high speed.
Wire the system as shown.
The LinkLogic
®
technology was specially designed for select Broan
and BEST ventilation devices to provide control and device sta-
tus information over existing power lines in the home. Extra control
wires are not required since compatible ventilation devices send
digital communication messages to each over the same wire that
LinkLogic
®
devices communicate via the power line. A phase cou-
pler is required if LinkLogic
®
damper control and master device
(such as LinkLogic
®
enabled range hood or SmartSense
®
control)
devices work as a coordinated system to ensure the home is being
ventilated at an optimum, energy efficient manner.
LINKLOGIC
®
TECHNOLOGY