P195P Installation-Guide
- 5 -
AIR
AIR
GRILL
(Not supplied)
8” ROUND
DUCT AND
ELBOW
DUCT
CONNECTOR
HOOD
MAKE-UP
AIR DAMPER
MARKING
MARKED
“120 VAC INPUT”
MOUNTING SCREWS
(3,9 x 9,5mm)
P195PM70 Models
MAKE-UP
AIR DAMPER
MARKING
MARKED
“120 VAC INPUT”
MOUNTING SCREWS
(3,9 x 9,5mm)
P195P1M52 Model
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only
metal ductwork.
1. Decide where to install the duct.
2. A straight, short duct will allow the hood to
perform most efficiently.
3. Long duct, elbows, and transitions will
reduce the performance of the hood. Use
as few of them as possible.
4. Use duct tape to seal the joints between
ductwork sections.
Ducted configuration
(shown in Fig.1a):
Install a roof or wall cap. Connect 8" round metal
ductwork to cap and work back towards hood
location.
Non-Ducted configuration
(shown in Fig.1b):
Install a decorative grill (not supplied by Best).
You may need to purchase a round-to-
rectangular transition depending on your
application.
DUCTED CONFIGURATION
ROOF CAP
8” ROUND
DUCT
WALL
CAP
HOOD
24” TO 30” ABOVE
COOKING SURFACE
8” ROUND
ELBOW
INSTALL JUNCTION BOXES
1. In the area marked “120 VAC INPUT”,
place a junction box on the top of the
hood. Run the wires through the hole
below and secure with (2) 3,9 x9,5 screws
and (2) washers. See Fig.3-4.
2. Repeat with the second junction box in
the area marked "Relay Contact
(30VRMS, MAX) Connection fot Broan
Make-up Air Damper Models MD6T/
MD8T".
MOUNTING SCREWS
(3.9x9.5mm)
REMOVE THE TAPE
INSTALL DUCT CONNECTOR
1. Install the damper duct connector onto the
hood using mounting screws (3,9x9,5mm)
as shown in Fig.2
2. Remove the tape located on the damper.
See Fig.2.
Fig.1a
Fig.2
Fig.3
Fig.4
Fig.1b
NON-DUCTED CONFIGURATION