Specification Sheet

BESTRANGEHOODS.COM
USA 800-558-1711
BESTRANGEHOODS.CA
CANADA 800-567-3855
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at .01 in. static pressure, based
on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
55 22
LIMITED
WARRANTY
YEARS ON PARTS YEARS ON LABOR
/
Installation height above the cooking surface: 24"–36"
HVI PERFORMANCE
INTERNAL BLOWER – IPB9IQ
SONES
Normal Medium* High* Boost
0.4 4.0 7.5 11.5
CFM
Normal Medium* High*
Boost
0.25 in. w.g.
Boost
0.1 in. w.g.
295 615 880 1020 1100
* Where noted performance rating is not HVI certified but was established in accordance
with HVI Standardized test procedure.
AIRFLOW PERFORMANCE
0
0.5
1
1.5
2
2.5
400200600 8001000 12
00
Static pressure
(in.w.g.)
Airflow
(cfm)
Vertical High Speed – 10" round
Vertical High Speed – 10" round
HOOD SIZES*
Internal Blower, Single – Depth 27''
48" IPB9IQT48SB
External (blower sold separately) – Depth 27''
48" IPB9E48SB
* For exact dimensions, please refer to the technical drawing of each model.
FEATURES
Finish Brushed Stainless Steel (Grade 430)
Lighting Type Halogen, T4, G9, 25W
Number of Lamps 4
Lighting Levels 2
Lighting Lamps Included Yes
Control Type 3-speed Plus Boost Electronic
Pushbutton with Display
Control Features Heat Sentry™, Delay Off, Filter Clean
Reminder
Remote Control Optional ACR3
Fil ter Typ e Hi-Flow Baffle
Non-ducted Capability No
HOOD BLOWER INCLUDED IPB9IQ
Internal iQ12
Max Blower CFM* 1500
HOOD BLOWER OPTIONS (blowers sold separately)
Refer to external blower's specification sheets for HVI performance
(sones and CFM).
External In-line ILB3 ILB6 ILB9 ILB11
Max Blower CFM* 300 675 900 1500
External Exterior EB6 EB9 EB12 EB15
Max Blower CFM* 665 890 1300 1650
ACCESSORIES
10'–11' Flue Extension (ducted) AEIPB9SB
Universal MUA Damper MD6TU, MD8TU, MD10TU
(RequiresFresh Air Inlet)
Fresh Air Inlet 641FA, 643FA, 610FA
INSTALLATION REQUIREMENTS
Amps @ 120V: Internal Blower 8.5
Electrical Connection Direct Wire
Duct Size: Internal Blower 10"
Duct Size: External Blower 10"
Duct Direction Vertical
Backdraft Damper Included
*MAX Blower CFM indicates the performance of the hood blower in open air.
99045187E 10/21
IPB9 Series
ISLAND
Telescopic flue for 8'–9' ceiling is standard.
Optional flue extensions for 10'–11' ceiling.
3-1/8
min. 34 - max. 48
29-7/8
20-1/
2
14-3/4
19
27
48