Installation Guide

- 9 -
HD0231
INSTALLATION WITH
DRY WALL TRIM ATDIP SERIES
8. INSTALL BLOWER HOUSING
Use both screws (A) previously removed in step 4 to assemble the blower housing to the mounting brackets. For installation with decorative
flue cover AEIWP Series only, place 4 nuts (B) (from flue cover parts bag) on the pem studs, leaving 1/4” for the hood installation. The
blower housing must be installed in such a way that its label (C) will be on the same side as the hood control side. See illustrations below.
HD0230
INSTALLATION WITH
DECORATIVE FLUE COVER AEIWP SERIES
A
B
B
Model 423, 424, 427 453, or 454
Attach transition (if required) to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
NOTE: Model P6 blower plate connects directly to 7’ round ductwork without a transition.
HO0086
10.INSTALL TRANSITION TO ROUGH-IN PLATE (INTERIOR BLOWER ONLY)
11. INSTALL THE ROUGH-IN PLATE IN THE BLOWER HOUSING
Run power cable to installation location. Refer to the instructions included with
the selected blower/rough-in kit (sold separately) for details on installing the
rough-in plate. Install the rough-in plate so that the wiring box is located on the
right side when facing the hood, as specified on the blower housing label.
Connect transition or rough-in plate to ductwork. Use metal duct tape to make
all joints secure and air-tight.
HD0232
C
C
WIRING COVER
A
From the inside, secure the blower housing to mounting brackets, using 2 no. 8 x 3/8”
screws per side.
Screws must be installed in embossed sections, see details beside.
HO0100
9. SECURE BLOWER HOUSING TO BRACKETS
RETAINING SCREWS LOCATION