Specification Sheet

CP57IQ SERIES HOOD SYSTEM
To minimize the gap around the power pack, take actual width and depth measurements of power pack and add 1/16” to get D and E
measurements. Cut the hole in the bottom of the cabinet according to dimensions. See chart and illustration for details.
POWER PACK CUTOUT DIMENSIONS
SERIES WIDTH DE
CP57IQ
36” 19
3
8 34½”
48” 19
3
8”” 46½”
48” 22
5
8 46½”
54” 22
5
8 52½”
60” 22
5
8 58½”
66” 22
5
8 64½”
E
D
HL0249
MODEL 418
(10” ROUND
ADJUSTABLE ELBOW)
MODEL 410
(10” ROUND DUCT
— 2 FT. SECTIONS)
10 ROUND VERTICAL
IN-LINE DAMPER (INCLUDED WITH
CP57IQ SERIES HOOD)
MODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL 441
(10’ ROUND WALL CAP)
DUAL iQ12 BLOWER (1200 CFM)
(INCLUDED)
CP57IQ SERIES
HOOD
All duct and blower accessories sold
separately unless noted otherwise.
HVI PERFORMANCE
Duct Orientation Size
Sones CFM
Normal Medium* High* Boost Normal Medium* High*
Boost
0.25 in. w.g.
Boost
0.1 in. w.g.
Round - Vertical 10 in. 0.3 4.0 7.0 11.0 290 625 875 1050 1100