Installation Guide

- 15 -
FIG. 21
2-WIRE PLUS GROUND
120 VAC LINE IN
KNOCKOUTS
120VAC 60Hz
LINE-IN
FIG. 22
BOX MARKED
“120VAC INPUT”
CONNECT
WHITE-TO-WHITE
BLACK-TO-BLACK
GREEN-TO-GROUND
CONNECT THE WIRING
WARNING: All electrical wiring
should be done by a qualifi ed person (s) in
accordance with all applicable codes and
standards. This range hood must be properly
grounded.
1. Remove electrical compartment cover by
removing (2) screws (Fig.20).
2. Run 2-wire plus ground, 120 VAC electrical
power cable to the ¾” knockout located on
the back of the hood. Fig. 21.
3. Remove ¾” electrical knockout from the
back of the hood.
4. From the electrical box marked “120 VAC
Inlet”, remove (2) screws that secure the
cover to the metal wiring box. Fig. 22.
5. Pull 120VAC electrical power cable into
the box and secure with an appropriate
cable clamp.
6. Make electrical connections inside the box.
Connect white-to-white, black-to-black and
green-to-ground.
7. Replace the wiring box cover and the
screws. Reinstall electrical compartment
cover and screws. Make sure wires are
not pinched between the cover and box.
FIG. 20
ELECTRICAL
COMPARTMENT
COVER