Specification Sheet

BESTRANGEHOODS.COM
USA 800-558-1711
BESTRANGEHOODS.CA
CANADA 800-567-3855
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at .01 in. static pressure, based
on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
55 22
LIMITED
WARRANTY
YEARS ON PARTS YEARS ON LABOR
/
99045164E 10/21
37-1/4
27-1/2
43-1/4
1-1/2
22
24-3/8
min 9-7/16
max 13-3/4
6-1/8
CC34-43" Series
37-1/4
27-1/2
43-1/4
1-1/2
22
24-3/8
min 13-3/4
max 22-1/4
10-1/2
11-3/8
Model CC34IQSB – 8" Round
Model CC34E6SB – 8" Round
HOOD SIZES*
Internal Blower, Single – Depth 27-1/2''
43" CC34IQSB
External (blower sold separately) – Depth 27-1/2''
43" CC34E6SB
* For exact dimensions, please refer to the technical drawing of each model.
FEATURES
Finish Brushed Stainless Steel (Grade 430)
Lighting Type LED
Number of Lamps 6 lamps (3W each, 660 lumens total,
2800–3200K)
Lighting Levels 3
Lighting Lamps Included Yes
Control Type 4-speed Electronic Light Touch
Control Features Delay-off, Filter Clean Reminder
Remote Control ACR3 Included
Filter Type Mesh Grease Perimeter Aspiration
Non-ducted Capability Yes
HOOD BLOWER INCLUDED CC34IQ
Internal iQ6
1
Max Blower CFM* 800
1
If needed, ask a recommended installer to limit discharge to 300 or 400 CFM.
HOOD BLOWER OPTIONS (blowers sold separately)
Refer to external blower's specification sheets for HVI performance
(sones and CFM).
External In-line ILB3 ILB6 ILB9 ILB11
Max Blower CFM* 300 675 900 1500
External Exterior EB6 EB9 EB12 EB15
Max Blower CFM* 665 890 1300 1650
ACCESSORIES
Non-Duct Kit ANKCC34
Charcoal Replacement Filter AFCCC34
Automatic MUA Damper MD6TU, MD8TU, MD10TU
(Requires Fresh Air Inlet)
Fresh Air Inlet 641FA, 643FA, 610FA
White Glass Panels AGPCC34W
INSTALLATION REQUIREMENTS
Amps @ 120V: Internal Blower 4.0
Electrical Connection Direct Wire
Duct Size: Internal Blower 8"
Duct Direction Horizontal,
Vertical (External vent only)
Backdraft Damper Included
*MAX Blower CFM indicates the performance of the hood blower in open air.
If needed, ask a recommended
installer to limit discharge to
300 or 400 CFM.
HVI PERFORMANCE
INTERNAL BLOWER – CC34IQ
SONES
Speed 1 Speed 2* Speed 3* Speed 4
<0.3 2.0 5.5 9.5
CFM
Speed 1 Speed 2* Speed 3*
Boost
0.25 in. w.g.
Boost
0.1 in. w.g.
150 290 450 560 600
* Where noted performance rating is not HVI certified but was established in accordance
with HVI Standardized test procedure.
AIRFLOW PERFORMANCE
0
0.5
1
1.5
2
2.5
40020
06
00 80
0
Static pressure
(in.w.g.)
Airflow (cfm)
Vertical High Speed – 8"
Vertical High Speed – 8"
Installation height above the cooking surface: 48"–84"
The minimum hood distance above the cooktop must not
be lessthan48". A maximum of 84" above the cooktop is
highly recommended for best capture of cooking impurities.
Distances over 84" are at the installer and user’s discretion.
BUILT-IN HOOD