CALIBRATE IQ BLOWER 
SYSTEM
TM
After the hood is installed and wired, 
engage the calibration process (our 
Guaranteed Performance System 
Technology to ensure full-rated air ow is 
being delivered). Prior to calibration, ensure 
that all  lters, light bulbs and duct system 
are installed.
CALIBRATION PROCESS Fig. 27
Hold the calibration button for 3 seconds; 
calibration button will light up and stay on 
for up to 13 minutes. The blower will start 
and begin the calibration process. When 
calibration is complete, one of two things 
will occur:
FIG. 27
CALIBRATION 
LIGHT
CALIBRATION 
BUTTON
1.The blower turns o  and calibration button light stays on = Successful calibration. Press 
the button to turn o  the LED. Note: The LED will also turn o  if you select any blower 
speed on the control.
2.The blower turns o  and calibration button light blinks continuously = Too much 
restriction in the ductwork is preventing the IQ Blower System™ from achieving the rated 
air ow. The blower is automatically set to maximum intensity. NOTE: Common items that 
cause restrictions: restricted damper  ap(backdraft damper, wall cap, roof cap), too many 
elbows, duct size less than 80% of hood outlet, poor transition, use of  ex ducting and/or 
crushed ducting. 
Three options are available if your hood system has too much restriction:
1. Accept air ow as is.
  a. Press the calibration button to accept air ow as is. The IQ Blower System™ is now 
con gured to the highest possible performance. The blinking calibration light goes out. 
Note: The LED will also turn o  if you select any blower speed on the control.
2. Correct duct restriction, clear the original calibration data, and repeat the calibration 
process. 
  a. Correct the duct restriction.
  b. Clear the original calibration data by holding calibration button for 10 seconds. The light 
will blink 3 times to con rm and the blower con guration will go back to default settings. 
  c. Repeat calibration process from the beginning.
3. Clear calibration data to reset hood to default factory setting and achieve standard high 
pressure blower performance.
  a. Clear calibration data and reset hood to factory default setting by holding calibration 
button for 10 seconds. The light will blink 3 times to con rm and the blower con guration 
will go back to default settings.